Ref. Not Lock
Meaning: Cannot synchronize with the reference signal.
The reference signal or FM-81 Board may be
defective.
Remedy: Confirm that the reference signal correct. If
they are correct, the FM-81 Board may be
defective.
DM1 File Open Fail
Meaning: Upon startup, failed to allocate space for the
LIVE1 material for R1 and P1 ports in
DTR+PANEL or DTR+DTR mode. R1 and P1
ports cannot be controlled from the DTR-3000.
A recording time exceeding recording capacity
may be set for LIVE DURATION (menu 034)
on the basic menu.
Remedy: Press the TOTAL/REMAIN button and confirm
the settings for SysRemain (HDD available
space) and "LIVE DURATION" (menu 034) on
the basic menu. When the operation mode is
DTR+Panel, this warning occurs if the "LIVE
DURATION" setting for DTR-1 exceeds
SysRemain. When the operation mode is
DTR+DTR, this warning occurs if the LIVE
DURATION settings for DTR-1 plus DTR-2
plus three minutes exceeds SysRemain. Correct
the LIVE DURATION settings, then reboot the
unit.
DM2 File Open Fail
Meaning: Upon startup, failed to allocate space for the
LIVE2 material for R2 and P2 ports in DTR +
DTR mode. R2 and P2 ports cannot be
controlled from the DTR-3000. A recording
time exceeding recording capacity may have
been set for LIVE DURATION (menu 034) on
the basic menu.
Remedy: See "DM1 File Open Fail."
EM Board Warning
Meaning: Detected a malfunction on the EM-3 Board.
The EM-3 Board may be defective.
FM Board Warning
Meaning: Detected a malfunction on the FM-81 Board.
The FM-81 Board may be defective.
FM Battery Warning
Meaning: Detected a malfunction in the battery that
maintains settings on the FM-81 Board.
The battery may be discharged.
R1 port Warning
Meaning: Detected a malfunction in the R1 port control
area.
The DM-127 Board and DEC-136/ENC-72
Board may be defective.
R2 port Warning
Meaning: Detected a malfunction in the R2 port control
area.
The DM-127 Board and DEC-136/ENC-72
Board may be defective.
R3 port Warning
Meaning: Detected a malfunction in the R3 port control
area.
The DM-127 Board and DEC-136/ENC-72
Board may be defective.
P1 port Warning
Meaning: Detected a malfunction in the P1 port control
area.
The DM-127 Board and DEC-136/ENC-72
Board may be defective.
P2 port Warning
Meaning: Detected a malfunction in the P2 port control
area.
The DM-127 Board and DEC-136/ENC-72
Board may be defective.
P3 port Warning
Meaning: Detected a malfunction in the P3 port control
area.
The DM-127 Board and DEC-136/ENC-72
Board may be defective.
RAID SBX(U) Warning
Meaning: Detected a malfunction in communications
between the FM-81 Board and RAID.
The FM-81 Board and PU-121 Board may be
defective.
RAID SBX(D) Warning
Meaning: Detected a malfunction in communications with
the FM-81 Board in the PU-121 Board.
The FM-81 Board and PU-121 Board may be
defective.
RAID Battery Warning
Meaning: Detected a malfunction in the battery that
maintains PU-121 Board settings.
The battery may be discharged.
RAID Flash Warning
Meaning: A Flash ROM malfunction detected in the PU-
121 Board.
The PU-121 Board may be defective.
HDD xx Warning
Meaning: Errors occur frequently while reading/writing
HDD number xx.
HDD xx Fail
Meaning: HDD number xx cannot be used due to
malfunction.
A-3 (E)
Error Messages