Page 1
T834C,T8034C Heating-Cooling Triple Fuel Thermostats INSTALLATION INSTRUCTIONS APPLICATION the T834C and T8034C Thermostats applicable to almost all single-stage heating applications. See Table 1 for The T834C, T8034C Heating-Cooling Triple Fuel Thermo- specific models and applications. An spdt mercury switch stats, see Fig. 1, control 24 to 30 Vac single-stage heating- makes R to W on a temperature fall for heating, and R to Y cooling systems.
All wiring must comply with local codes and ordinances. instructions regarding recycling and the proper disposal of this control. The T834C Thermostat can be mounted directly on a wall or on a vertical or horizontal outlet box. The 209649A (taupe) Mounting Plate Assembly allows mounting on a...
Page 3
IN GAS-AND OIL-FIRED APPLICATIONS, JUMPER TERMINALS 1 AND Y FOR AUTOMATIC FAN CONTROL IN COOLING. M11341 JUMPER W-Y FOR SINGLE STAGE HEAT PUMP APPLICATIONS. Fig. 2. Jumpering T834C and T8034C terminals for fan control. FAN SWITCH FAN RELAY AUTO (HOT)
System and Fan Switching If the current rating is not available, proceed as follows to determine the rating: The T834C and T8034C feature SYSTEM and FAN Turn off the power. switches for control of the heating-cooling and fan systems. Wire the thermostat, but do not mount it on the wall.
Page 5
T834C,T8034C HEATING-COOLING TRIPLE FUEL THERMOSTATS Adjust the heat anticipator to match the reading on Cooling the ammeter. Disconnect the ammeter, reconnect the W wire, and CAUTION mount the thermostat. Continue with system checkout. Do not operate cooling if outdoor temperature is below 50°F (10°C).
Page 6
T834C,T8034C HEATING-COOLING TRIPLE FUEL THERMOSTATS Move the setting lever to a lower setting. Wait at COIL SHOWN WITHOUT least five minutes for the temperature to stabilize. HEAT ANTICIPATOR Slowly move the setting lever until it reads the same as the thermometer.