Parameter Setting; Basic Settings (Analog Input) - Mitsubishi Electric MELSEC iQ-F FX5 User Manual

Programmable controllers
Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

4.7

Parameter Setting

Set the parameters of each channel.
Setting parameters here eliminates the need to program them.
Parameters are enabled when the CPU module is powered ON or after a reset. In addition, operations
different from the parameter settings are possible by transferring values to special relays and special registers
while changing these values in the program.
Refer to Page 170 List of Special Relays or Page 171 List of Special Registers for details on the
special relays and special registers.

Basic settings (Analog input)

Setting procedure
Open "Basic Settings" of the GX Works3.
1.
Start Module parameter.
Navigation window  [Parameter]  [FX5UCPU]  [Module Parameter]  [Analog Input]  "Basic Settings"
Window
Displayed items
Item
A/D Conversion Enable/Disable
Setting
Average Processing Specify
Time Average Counts Average
Moving average
2.
Click the item to be changed to enter the setting value.
• Item where a value is selected from the pull-down list
Click [] button of the item to be set, and from the pull-down list that appears, select the value.
• Item where a value is entered into the text box
Double-click the item to be set to enter the numeric value.
4 FX5U CPU MODULE BUILT-IN ANALOG
164
4.7 Parameter Setting
Description
Set whether to "enable" or "disable" A/D conversion value output.
Execute whether to set "average process" or "sampling
processing".
Set time average, count average, moving average counts during
specifying average process for each channel.
Setting range
• Enable
• Disable
• Sampling
• Time Average
• Count Average
• Moving average
User-defined value for the
allowable setting range
Default
Disable
Sampling
0