Managing the System Time and Date
Command
Step 4
show running-config
Step 5
copy running-config startup-config
The minutes-offset variable in the clock timezone global configuration command is available for those
cases where a local time zone is a percentage of an hour different from UTC. For example, the time zone
for some sections of Atlantic Canada (AST) is UTC-3.5, where the 3 means 3 hours and.5 means 50
percent. In this case, the necessary command is clock timezone AST -3 30.
To set the time to UTC, use the no clock timezone global configuration command.
Configuring Summer Time (Daylight Saving Time)
Beginning in privileged EXEC mode, follow these steps to configure summer time (daylight saving time)
in areas where it starts and ends on a particular day of the week each year:
Command
Step 1
configure terminal
Step 2
clock summer-time zone recurring
[week day month hh:mm week day month
hh:mm [offset]]
Step 3
end
Step 4
show running-config
Step 5
copy running-config startup-config
The first part of the clock summer-time global configuration command specifies when summer time
begins, and the second part specifies when it ends. All times are relative to the local time zone. The start
time is relative to standard time. The end time is relative to summer time. If the starting month is after
the ending month, the system assumes that you are in the southern hemisphere.
This example shows how to specify that summer time starts on the first Sunday in April at 02:00 and
ends on the last Sunday in October at 02:00:
Switch(config)# clock summer-time PDT recurring 1 Sunday April 2:00 last Sunday October
2:00
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
1-6
Purpose
Verify your entries.
(Optional) Save your entries in the configuration file.
Purpose
Enter global configuration mode.
Configure summer time to start and end on the specified days every year.
Summer time is disabled by default. If you specify clock summer-time
zone recurring without parameters, the summer time rules default to the
United States rules.
For zone, specify the name of the time zone (for example, PDT) to be
displayed when summer time is in effect.
(Optional) For week, specify the week of the month (1 to 5 or last).
(Optional) For day, specify the day of the week (Sunday, Monday...).
(Optional) For month, specify the month (January, February...).
(Optional) For hh:mm, specify the time (24-hour format) in hours and
minutes.
(Optional) For offset, specify the number of minutes to add during
summer time. The default is 60.
Return to privileged EXEC mode.
Verify your entries.
(Optional) Save your entries in the configuration file.