Chapter 1
Configuring Interface Characteristics
You use the switch CLI to configure the XPS:
•
•
•
Configuring the System Names
To configure a name for the XPS 2200 system and for an XPS port connected to a switch, follow these
steps beginning in privileged EXEC mode:
Command
Step 1
configure terminal
Step 2
power xps switch-number name {name |
serialnumber}
Step 3
power xps switch-number port {name |
hostname | serialnumber}
Step 4
end
Step 5
show env xps system
Step 6
copy running-config startup-config
Use the no power xps switch-number name command to remove the system name. Use the no power
xps switch-number port command to remove the port name.
OL-25303-03
Configuring the System Names, page 1-49
Configuring XPS Ports, page 1-50
Configuring XPS Power Supplies, page 1-51
Purpose
Enters global configuration mode.
Configures a name for the XPS 2200 system.
The switch-number appears only on Catalyst 3750-X switches and
represents the switch number in the data stack, a value from 1 to 9.
Configures a name for an XPS 2200 port connected to the switch.
The switch-number appears only on Catalyst 3750-X switches and
represents the switch number in the data stack, a value from 1 to 9.
Returns to privileged EXEC mode.
Verifies the configured name of the system and ports.
(Optional) Saves your entries in the configuration file.
Configuring the Cisco eXpandable Power System (XPS) 2200
name—Enter a name for the XPS 2000 port. The name can have up
•
to 20 characters.
serialnumber—Use the serial number of the XPS 2200 as the system
•
name.
name—Enter a name for the XPS 2000 port.
•
hostname—Use the hostname of the switch connected to the port.
•
serialnumber—Use the serial number of the switch connected to the
•
port.
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
1-49