1)
Types of pulse output, positioning and other relevant instructions and their target output numbers
Classification
Pulse output
Positioning
High-speed
processing
*1.
Y002 (pulse output destination) cannot be specified when the 14-point or 24-point type FX
connected.
*2.
The pulse output destination Y003 can be specified only when two special high-speed output adapters are
connected to an FX
*3.
This function is supported only in FX
2)
When using the same output relay (Y000 or Y001) in several instructions.
While a pulse output monitor (BUSY/READY) flag is ON, a pulse output or positioning instruction for the same
output relay cannot be executed.
While a pulse output monitor flag is ON, even after the instruction drive contact is set to OFF, a pulse output or
positioning instruction for the same output relay cannot be executed.
Before executing a pulse output or positioning instruction, wait until the pulse output monitor flag turns OFF and
one or more operation cycles pass.
Pulse output destination device
Instruction
PLSY(FNC 57)
Pulse Y output
PLSR(FNC 59)
Acceleration/deceleration setup
DSZR(FNC150)
DOG search zero return
*3
Interrupt positioning
DVIT(FNC151)
ZRN(FNC156)
Zero return
PLSV(FNC157)
Variable speed pulse output
DRVI(FNC158)
Drive to increment
DRVA(FNC159)
Drive to absolute
PWM(FNC 58)
Pulse width modulation
PLC.
3U
/FX
3U
Pulse output monitor flag
Y000
Y001
13 High-Speed Processing – FNC 50 to FNC 59
13.10 FNC 59 – PLSR / Acceleration/Deceleration Setup
Instruction name
PLCs.
3UC
M8340
M8350
Target output numbers
Y000,Y001
Y000,Y001
*1
*2
Y000,Y001,Y002
,Y003
*2
Y000,Y001,Y002,Y003
*1
*2
Y000,Y001,Y002
,Y003
*1
*2
Y000,Y001,Y002
,Y003
*1
*2
Y000,Y001,Y002
,Y003
*1
*2
Y000,Y001,Y002
,Y003
*1
*2
Y000,Y001,Y002
,Y003
PLC is
3G
387
11
12
13
14
15
16
17
18
19
20