20.4
FNC155 – ABS / Absolute Current Value Read
Outline
This instruction reads the absolute position (ABS) data when the Mitsubishi servo amplifier (equipped with the
absolute position detection function) MR-H, MR-J2(S), or MR-J3 is connected. The data is converted into a pulse
when being read.
1. Instruction format
FNC 155
D
ABS
2. Set data
Operand type
S
D
1
D
2
3. Applicable devices
Bit Devices
Oper-
and
System User
Type
X Y M T C S D .b KnX KnY KnM KnS T C D R U \G
S
D
1
1
D
2
1: Specify a transistor output.
2: "D .b" is available only in FX
3: This function is supported only in FX
Explanation of function and operation
Command
input
FNC155
DABS
554
→ For explanation of the instruction, refer to the Positioning Control Edition.
Mnemonic
16-bit Instruction
−
Head device number inputting absolute (ABS) data output signal sent from servo amplifier
Three points are occupied from
Head device number outputting absolute (ABS) data control signal to servo amplifier
Three points are occupied from
Device number storing absolute (ABS) data (32-bit value)
Digit Specification
2
2
and FX
3U
3UC
/FX
3U
S
D
D
1
20.4 FNC155 – ABS / Absolute Current Value Read
Operation Condition
32-bit Instruction
Description
S
.
D
.
1
Word Devices
Special
System User
Unit
3
PLCs. However, index modifiers (V and Z) are not available.
PLCs.
3UC
2
20 Positioning Control – FNC150 to FNC159
Mnemonic
Operation Condition
13 steps
DABS
Others
Con-
Real
Index
stant
Number
V
Z Modify K H
E
Continuous
Operation
Data type
Bit
32-bit binary
Charac-
Pointer
ter String
" "
P