Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
4. Inputting and indicating a program using GX Developer
• Input a circuit for setting the initial state relay to ON using the relay ladder.
In this example, the initial state relay S0 is set to ON in a ladder block using the special auxiliary relay M8002 which
turns ON momentarily when the PLC mode is changed from STOP to RUN.
• When inputting a program using GX Developer, write a relay ladder program to a ladder block, and write an SFC
program to an SFC block.
• Programs expressing operations in state relays and transfer conditions are handled as internal circuits of the state
relays and transfer conditions.
Create each one using a relay ladder.
For details on the programming procedure in GX Developer, refer to GX Developer Operating Manual.
Write a circuit not
belonging to SFC to a
ladder block using a
relay ladder.
Write an SFC program
to an SFC block.
M8002
Ladder block
SFC block
0
1
2
3
4
5
RET
35 SFC Program and Step Ladder
Program for setting the initial state
SET
S0
relay to ON
Indicate the state relay number and
transfer condition number.
0
X000
TRAN
Y023
20
Y021
X001
TRAN
Y021
21
Y023
X002
TRAN
22
T0
T0
TRAN
Y023
23
Y021
X003
TRAN
Y021
24
Y023
X002
TRAN
S0
When a program is input using GX Developer,
END
"RET" and "END" are automatically written.
35.1 SFC Program
Input them as
K50
internal circuits.