Appendix A-1-2
Cautions on writing during RUN
"In the FX
, FX
3G
3U
following programming tools."
Programming tools which support writing during RUN
• Japanese version
Programming tool
*1
GX Works2
(SW DNC-GXW2-J)
FX
3U
*2
GX Developer
(SW D5C-GPPW-J)
FX
3U
*2
FX-PCS/WIN
FX
3U
*1.
Write during RUN is not possible with a SFC program.
*2.
Write during RUN is not possible with a list program or a SFC program.
and FX
PLCs, writing is enabled during RUN (program changes during RUN mode) using the
3UC
→ For the operating procedure of and cautions on writing during RUN,
PLC
Version
FX
Ver. 1.07H or later
3G
Ver. 1.07H or later
/FX
3UC
Ver. 1.45X or later
Ver. 2.00A or later
Ver. 5.00A or later
FX
3G
Ver. 8.72A or later
Ver. 8.76E or later
Ver. 7.00A or later
Ver. 8.13P or later
Ver. 8.18U or later
/FX
3UC
Ver. 8.23Z or later
Ver. 8.29F or later
Ver. 8.82L or later
FX
Ver. 4.00 or later
3G
Ver. 1.00 or later
/FX
Ver. 2.00 or later
3UC
Ver. 4.20 or later
A Programming Tool Applicability and Version Upgrade History
refer to the respective programming tool manual.
Writing in the instruction and device ranges during RUN is supported in FX
PLCs Ver. 1.10.
Writing in the instruction and device ranges during RUN is supported in FX
FX
PLCs earlier than Ver. 2.70.
3UC
Writing in the instruction and device ranges during RUN is supported in FX
FX
PLCs Ver. 2.70.
3UC
Writing in the instruction and device ranges during RUN is supported in FX
PLCs Ver. 1.00.
Writing in the instruction and device ranges during RUN is supported in FX
PLCs Ver. 1.00.
Writing in the instruction and device ranges during RUN is supported in FX
PLCs earlier than Ver. 1.10.
Writing in the instruction and device ranges during RUN is supported in FX
PLCs Ver. 1.10.
Writing in the instruction and device ranges during RUN is supported in FX
PLCs Ver. 3.00.
Writing in the instruction and device ranges during RUN is supported in FX
PLCs earlier than Ver. 1.30.
Writing in the instruction and device ranges during RUN is supported in FX
PLCs earlier than Ver. 2.20.
Writing in the instruction and device ranges during RUN is supported in FX
FX
PLCs earlier than Ver. 2.30.
3UC
Writing in the instruction and device ranges during RUN is supported in FX
FX
PLCs earlier than Ver. 2.61.
3UC
Writing in the instruction and device ranges during RUN is supported in FX
FX
PLCs Ver. 2.61.
3UC
Writing in the instruction and device ranges during RUN is supported in FX
PLCs Ver. 1.00.
Writing in the instruction and device ranges during RUN is supported in FX
PLCs Ver. 3.30.
Writing in the instruction and device ranges during RUN is supported in FX
PLCs Ver. 1.00.
Writing in the instruction and device ranges during RUN is supported in FX
PLCs Ver. 3.00.
A-1 Programming Tool Applicability
Remarks
31
32
3G
33
and
3U
and
3U
2N
1N
34
3G
3G
2N
35
3UC
3UC
and
3U
and
3U
36
and
3U
1N
2
37
2N
2N
38
A
B
895

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3uc series

Table of Contents