hit counter script

Mitsubishi Electric FX3G SERIES Programming Manual page 696

Programmable controllers
Hide thumbs Also See for FX3G SERIES:
Table of Contents

Advertisement

FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
2. Related devices
Number
ch1
ch2
M8029
M8063
M8438
M8151
M8156
M8152
M8157
M8153
M8158
M8154
M8159
*1.
Cleared when PLC power supply is turned from OFF to ON.
*2.
Cleared when the PLC mode switches from STOP to RUN.
*3.
Initial value: -1
Cautions
• It is not permitted to use an "RS (FNC 80)/RS2 (FNC 87)"/"FLCRT (FNC300) to FLSTRD (FNC305)" instruction and
an "IVCK (FNC270) to IVMC (FNC275)" instruction for the same port.
• Two or more inverter communication instructions (FNC270 to FNC275) can be driven for the same port at the same
time.
• Cautions on using the password function in the D700 Series.
1)
When a communication error occurs
When a communication error occurs in an inverter communication instruction, the FX PLC automatically retries
communication up to 3 times
Accordingly, note that the number of times of password reset error displayed in accordance with the setting of
Pr297 may not agree with the actual number of times of password input error as described below when a
password reset error occurs in the D700 Series in which "display of the number of times of password reset error"
is made valid using Pr297.
Do not execute automatic retry (re-driving of an inverter instruction) using a sequence program when writing data
to Pr297.
Cases in which a password reset error occurs in an inverter communication instruction, and the actual number of
times of reset error in such cases.
-
When a wrong password is written to Pr297 due to a password input error
When the writing instruction is executed once, a password reset error occurs 3 times.
-
When the password cannot be written correctly to Pr297 due to noise, etc.
A password reset error occurs up to 3 times.
2)
When registering the password
When registering the password in the D700 Series inverter using an inverter communication instruction, write the
password to Pr297, read Pr297, and then confirm that registration of the password is completed normally
If writing of the password to Pr297 is not completed normally due to noise, etc., the FX PLC automatically retries
writing, and the registered password may be reset by the retry.
*1.
The FX PLC executes the first communication, and then retries communication twice (3 time in total).
*2.
When "display of the number of times of password reset error" is made valid in the D700 Series using Pr297
and when a password reset error occurs 5 times, the "reading/writing restriction" cannot be reset even if the
right password is input.
For recovery from this status, it is necessary to all-clear all parameters in the D700 Series.
*3.
When the value given as a result of reading Pr297 is "0" to "4", registration of the password is completed
normally.
PLC applicable version
The table below shows PLC versions applicable to each inverter.
PLC
FX
3G
FX
3U
FX
3UC
694
→ For the instruction execution complete flag use method, refer to Subsection 6.5.2.
Description
Instruction execution complete
Serial communication error
*1
Inverter communicating
*2
Inverter communication error
Inverter communication error latch
*2
IVBWR instruction error
→ For other cautions, refer to the Data Communication Edition manual.
*1
.
FREQROL-V500/F500/A500/E500/S500
Ver. 2.20 or later
Ver. 1.00 or later
30 External Device Communication (Inverter Communication) – FNC270 to FNC275
30.4 FNC273 – IVWR / Inverter Parameter Write
Number
ch1
ch2
D8063
D8438
Error code of serial communication error
D8150
D8155
Response wait time in inverter communication
D8151
D8156
Step number in inverter communication
D8152
D8157
Error code of inverter communication error
Latch of inverter communication error
*2
D8153
D8158
occurrence step
D8154
D8159
IVBWR instruction error parameter number
FREQROL-F700/A700
Ver. 1.10 or later
Ver. 2.20 or later
Description
*1
*1
*3
*2
*2*3
*2*3
*3
.
FREQROL-E700/D700
Ver. 2.32 or later
Ver. 2.32 or later
*2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3uc series

Table of Contents