FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
Operation output setting (SET [1] or RESET [0]) [Up to 16 points]
Operation
1 0 1 0 0 1 1 1 0 0 0 1 0 1 1 0
output setting
Operation output setting
= HA716
In the case of "
Y000, n = K10"
1)
When this instruction is executed, the data table is set as the comparison target.
2)
When the current value of the high-speed counter, specified in
comparison value in the data table, the corresponding operation output specified in the data table is output to
D
to
If an output (Y) is specified in
refresh executed by the END instruction.
When specifying an output (Y), make sure that the least significant digit of the device number is "0".
Examples: Y000, Y010 and Y020
3)
Immediately after step 2), "1" is added to the current table counter value D8138.
4)
The next comparison point is set as the comparison target data.
5)
Steps 2) and 3) are repeated until the current value of the table counter D8138 becomes "m".
When the current value becomes "m", the instruction execution complete flag M8138 turns ON, and the execution
returns to step 1). At this time, the table counter D8138 is reset to "0".
6)
When the command contact is set to OFF, execution of the instruction is stopped and the table counter D8138 is
reset to "0".
708
A
7
1
D
=
Y
Y
Y
Y
Y
Y
Y
0
0
0
0
0
0
0
1
1
0
0
0
0
0
1
0
7
6
5
4
3
D
+n-1
D
+n-1.
D
, the output processing is executed immediately without waiting for the output
32 High-Speed Processing 2 – FNC280 to FNC289
32.1 FNC280 – HSCT / High-Speed Counter Compare With Data Table
6
When the current value of the high-speed counter
becomes equivalent to the comparison value, the
operation output setting pattern is output.
:ON
:OFF
Y
Y
Y
0
0
0
0
0
0
2
1
0
D
S
, becomes equivalent to the
2