C.10 Diagnostics
LCD display
Meaning
S:0
The device was unable to get a
measurement within the Failsafe LOE
Timer period. Possible causes: faulty
installation, antenna material buildup,
foaming/other adverse process
conditions, invalid calibration range.
S:2
Unable to collect profile because of a
power condition that is outside the
operating range of the device.
S:3
Device is nearing its lifetime limit
according to the value set in
Maintenance Required Limit.
S:4
Device is nearing its lifetime limit
according to the value set in
Maintenance Demanded Limit.
S:6
Sensor is nearing its lifetime limit
according to the value set in
Maintenance Required Limit.
S:7
Sensor is nearing its lifetime limit
according to the value set in
Maintenance Demanded Limit.
S:8
Service interval as defined in
Maintenance Required Limit has expired.
S:9
Service interval as defined in
Maintenance Demanded Limit
has expired.
S:10
Input parameters High Calibration Point
and Low Calibration Point are the same.
S:11
Internal temperature sensor failure.
276
Acyclic Extended Diagnostics /General Fault Codes
Corrective Action
Ensure installation details are correct.
Ensure no antenna material
buildup. Clean if necessary.
Adjust process conditions to minimize
foam or other adverse conditions.
Correct range calibration.
If fault persists, contact your local
Siemens representative.
Repair required. Contact your local
Siemens representative.
Replacement is recommended.
Replacement is recommended.
Replacement is recommended.
Replacement is recommended.
Perform service
Perform service.
Check calibration settings of device.
Ensure settings for High Calibration
Point and Low Calibration Point are
different.
Repair required. Contact your local
Siemens representative.