6
"Program" operating area
6.5
Multi-channel step sequence programming (option)
Significance of icon
background color
Green:
Yellow:
Red:
6-274
initially "up-to-date". Making changes can lead to programs being
marked with "Data modified".
When you change back to standardized view and back to
synchronized view all programs are re-synchronized and displayed as
"up-to-date".
If you position the cursor on a synchronization icon additional states
from a channel view are shown by means of the icon's background
colors.
Correct synchronization step -> The synchronization syntax/parameter
assignment specified in the configuration file SEDITOR.INI is
recognized. All addressed partners are found.
Cursor on synchronization icon: The channel is affected by this
synchronization and synchronization partner found.
Not all partners can be checked: A channel number cannot be
opened. At least one channel is addressed in the synchronization
syntax that is not contained in workpiece.DAT. There may be an error
in the program.
Cursor on synchronization icon: The channel is affected by this
synchronization, but at least one of the specified channel numbers is
not registered in the workpiece.DAT file.
Not all partners were found: An error is pending in the synchronization
syntax. Consequently, the synchronization syntax must be checked
and the faulty synchronization programming corrected in the
addressed channel.
Unsymmetrical channel numbers in respect of synchronization
partners found.
Examples are:
Channel C1 WAITM(99,1,2,3)
Channel C2 WAITM(99,1,2)
Channel C3 WAITM(99,1,3)
Cursor on synchronization icon:
In this channel, the partner was not found or the channel for the
synchronization icon which has the focus contains at least one
channel number from workpiece.DAT in which the partner being
searched for was not found.
Programming must be modified either in the selected channel (too
many or incorrect channel numbers specified) or in the searched
channel (missing synchronization).
SINUMERIK 840Di sl/840D sl/840D Operating Manual HMI-Advanced (BAD) - 01/2008 Edition
6
01/2008
© Siemens AG 2008 All rights reserved.