Chapter 4
Troubleshooting the Installation
•
The RP reset switch resets the RP and the entire system. To prevent system errors
Caution
and problems, use it only at the direction of a Cisco-certified service
representative.
Table 4-6
LED Display
LMEM
TEST
LCAH
INIT
BSS
INIT
NVRAM
INIT
EXPT
INIT
TLB
INIT
CACH
INIT
CACH
PARY
MEM
INIT
NVRAM
SIZE
OL-11636-01
Is a Critical, Major, or Minor alarm LED on the CSF card on?
If any of the three CSF card LEDs is on, a fault has been detected in the
–
system. Check the console for messages indicating the source of the
problem.
There could be a false error indication originating from the RP
–
(Table
4-6). You might want to reseat or replace the RP.
RP Alphanumeric LED Display Messages
1
Indications
Low memory test running
Lower 15k cache initialization
Initialize main memory for ROM
Initialize NVRAM
Initialize interrupt handlers
Initialize TLB
Initialize CPU data and instruction cache
Enable CPU cache parity
Initialize main memory
Size of the NVRAM
Cisco 12404 Internet Router Installation and Configuration Guide
Troubleshooting the Processor Subsystem
2
4-23