11. Press the release buttons on the top of the server and slide the operator
12. Pull the panel away from the rails and carefully pull the attached lightpath
13. If you are instructed to return the operator information panel assembly, follow

Installing the operator information panel assembly

To install the operator information panel, complete the following steps.
information panel assembly rails out of the server as far as it will go.
ribbon cable out of the server.
all packaging instructions, and use any packaging materials for shipping that
are supplied to you.
1. Read the safety information that begins on page vii and "Installation guidelines"
on page 39.
CD-RW cable connector
Air baffle
Lightpath cable connector
CD-RW cable retainer
Video cable
2. From the front of the server, thread the lightpath ribbon cable through the
panel housing in the server; then, carefully route and connect the ribbon cable
to the lightpath cable connector on the system board.
Operator information
panel
3. Slide the operator information panel into the server until it latches in place with
a click.
4. Reconnect the CD-RW cable 3 , the USB cable 2 , and the video cable 1
to the system board.
CD-RW cable
USB cable
Release button
Chapter 4. Removing and replacing server components
Video cable
connector
USB cable
connector
Fan 3
Interposer
card
Lightpath cable
93