Mitsubishi Electric FX5 User Manual page 39

Melsec iq-f series
Hide thumbs Also See for FX5:
Table of Contents

Advertisement

Device
Name
No.
SM9041
Data transfer sequence error
(Slave station 1)
SM9042
Data transfer sequence error
(Slave station 2)
SM9043
Data transfer sequence error
(Slave station 3)
SM9044
Data transfer sequence error
(Slave station 4)
SM9045
Data transfer sequence error
(Slave station 5)
SM9046
Data transfer sequence error
(Slave station 6)
SM9047
Data transfer sequence error
(Slave station 7)
SM9056
Data transfer sequence ON
SM9080
Station number settings SD
latch setting valid information
SM9081
Slave station quantity setting
SD latch setting valid
information
R: Read only, R/W: Read/Write, M: master station (station number 0), L: slave station (station number 1 to 7)
■FX3 Series compatible
Device
Name
No.
SM8063
Serial communication error
(CH1)
SM8438
Serial communication error
(CH2)
SM8183
Data communication error
(Master station)
SM8184
Data transfer sequence error
(Slave station 1)
SM8185
Data transfer sequence error
(Slave station 2)
SM8186
Data transfer sequence error
(Slave station 3)
SM8187
Data transfer sequence error
(Slave station 4)
SM8188
Data transfer sequence error
(Slave station 5)
SM8189
Data transfer sequence error
(Slave station 6)
SM8190
Data transfer sequence error
(Slave station 7)
SM8191
Data transfer sequence ON
R: Read only, M: Master station (station number 0), L: Slave station (station number 1 to 7)
Descriptions
Turns ON when data transfer sequence error of slave station
occurs
However, data sequence errors that occurred in the local
station (slave station) cannot be detected.
Remains ON while data transfer is being executed.
Turns ON when SD latch setting is set for the station number.
Turns ON when SD latch setting is set for the number of
slave stations setting.
Descriptions
Turns ON when error occurs in the serial communication with
the SM/SD compatible with FX3 Series being CH1.
Turns ON when error occurred in serial communication with
the SM/SD compatible with FX3 Series being CH2.
Turns ON when data transfer sequence error occurs in the
master station.
Turns ON when a data transfer sequence error occurs in
each slave station.
However, data sequence errors that occurred in the local
station (slave station) cannot be detected.
Remains ON while data transfer is being executed.
Dete
R/W
Available station
ction
Master
Slave stations
station
(Station
No. 0)
M,L
R
(Except station 1)
(Except station 2)
(Except station 3)
(Except station 4)
(Except station 5)
(Except station 6)
(Except station 7)
M,L
R
(Station 1 to 7)
M,L
R
(Station 1 to 7)
M,L
R
Dete
R/W
Available station
ction
Master
Slave stations
station
(Station
No. 0)
M,L
R
(Station 1 to 7)
M,L
R
(Station 1 to 7)
L
R
(Station 1 to 7)
M,L
R
(Except station 1)
(Except station 2)
(Except station 3)
(Except station 4)
(Except station 5)
(Except station 6)
(Except station 7)
M,L
R
(Station 1 to 7)
2 N:N NETWORK
2.9 Related Devices
2
37