Writing contents in case of (s2): K8, (s3): D200
Ex.
(s3)
D200
(s3)+1
D201
(s3)+2
D202
(s3)+3
D203
(s3)+14
D214
(s3)+15
D215
Processing details
Continuously writes parameter numbers and their values (2 words/parameter) for the number of points specified by (s2)
starting from word device specified by (s3) for station No. (s1) of inverter connected to communication channel (n) (no limit to
number of points that can be written).
Operation error
Operation errors pertaining to the instruction are as follows.
Operation Error Flag
SM0
SM1
ON
ON
ON
ON
4 INVERTER COMMUNICATION
112
4.8 Programming
Parameter No. 1
Parameter 1 value
Parameter No. 2
Parameter 2 value
(s2)×2 = Number of occupied word devices
Parameter No. 8
Parameter 8 value
Operation Error
Codes
SM56
SM8067
SD0
1810
2820
3405
3600
Description
SD8067
When specified channel is used with another instruction.
When specified device exceeds the device range.
When the value specified for (s1) is other than K0 to 31.
When the value specified for (s2) is less than K0.
When the value specified for (s3), ..., (s3) +2 ([s2] -1) is outside the range
that can be specified. (Less than K0, K3000 to 9999, K13000 to 32767)
When the value specified for (n) is other than K1 to 4.
When specified channel is not setting parameter.