Length

Use this element when an element indicating the data length is included in a packet.
• When sending: Calculates the data length of a specified range, and adds the result to a send packet.
• When receiving: Verifies the data (value) corresponding to the length in the received data as the data length of the specified
range.
For data examples of length, refer to Page 217 Data examples of Length.
Window
Item
Description
Element Name
Set the name of the element.
Code Type
Select a format of the data length.
• ASCII Hexadecimal
• ASCII Decimal
• HEX
Data Length
Select the data length on the line.
The range is 1 to 4.
Data Flow
Forward Direction
(Upper ByteLower Byte)
Reverse Direction
(Lower ByteUpper Byte)
Byte Swap
(by Word)
Calculating
Start
Select the start packet element numbers for the calculating range.
Range
The range is 1 to 32.
End
Select the last packet element numbers for the calculating range.
The range is 1 to 32.
Considerations for configuring packet element
• Only one terminator can be used in a packet.
• To configure the length, one or more other elements are needed.
When
Sends a calculated length from the upper byte.
sending
When
Receives data from the upper byte.
receiving
When
Sends a calculated length from the lower byte.
sending
When
Receives data from the lower byte.
receiving
When
Sends a calculated length swapping the upper byte and
sending
lower byte by word.
When
Receives data swapping the upper byte and lower byte
receiving
by word.
6 PREDEFINED PROTOCOL SUPPORT FUNCTION
6
Remarks
Data flow setting is
invalid when data length
is 1 byte.
Data flow setting is
invalid when data length
is 1 to 3 byte.
Refer to Page 219.