• Operation when preset input logic: positive logic, preset control switch: constant when ON
The preset is constantly executed while the preset input is ON.
ON
Preset input
OFF
ON
Count input
OFF
Current value
10
• Operation when preset input logic: negative logic, preset control switch: rising edge
The preset is executed when the preset input changes ON→OFF.
ON
Preset input
OFF
ON
Count input
OFF
Current value
10
• Operation when preset input logic: negative logic, preset control switch: falling edge
The preset is executed when the preset input changes OFF→ON.
ON
Preset input
OFF
ON
Count input
OFF
Current value
10