hit counter script

Mitsubishi Electric FX5 User Manual page 344

Melsec iq-f series
Hide thumbs Also See for FX5:
Table of Contents

Advertisement

No.
Name
SM8059
I00 disable (Counter interrupt disable)
SM8063
Serial communication error1 (ch1)
SM8067
Operation error
SM8068
Operation error latch
SM8072
Parallel link operation
SM8090
Block comparison signal
SM8099
High-speed ring counter
SM8151
Inverter communication (ch1)
SM8152
Inverter communication error (ch1)
SM8153
Inverter communication error latch (ch1)
SM8154
IVBWR instruction error (ch1)
SM8156
Inverter communication (ch2)
SM8157
Inverter communication error (ch2)
SM8158
Inverter communication error latch (ch2)
SM8159
IVBWR instruction error (ch2)
SM8161
8 bit operation mode
SM8168
SMOV data mode
SM8170
X0 pulse catch
SM8171
X1 pulse catch
SM8172
X2 pulse catch
SM8173
X3 pulse catch
SM8174
X4 pulse catch
SM8175
X5 pulse catch
SM8176
X6 pulse catch
SM8177
X7 pulse catch
SM8183
Data communication error (Master station)
SM8184
Data communication error (Slave station No.1)
SM8185
Data communication error (Slave station No.2)
SM8186
Data communication error (Slave station No.3)
SM8187
Data communication error (Slave station No.4)
SM8188
Data communication error (Slave station No.5)
SM8189
Data communication error (Slave station No.6)
SM8190
Data communication error (Slave station No.7)
SM8191
Data communication in execution
SM8246
LC46 counting direction monitoring
APPX
342
Appendix 1 Special Relay List
Description
OFF: Interrupt enabled
ON: Interrupt disabled
OFF: No error
ON: Error
OFF: No error
ON: Error
OFF: No error
ON: Error (latch)
OFF: In stopped state
ON: In normal running state
Block comparison signal ON when all comparison results are ON.
OFF: High-speed ring counter stop
ON: High-speed ring counter start
ON during inverter communication.
OFF: No error
ON: Error
OFF: No error
ON: Error (latch)
OFF: No error
ON: Error
ON during inverter communication.
OFF: No error
ON: Error
OFF: No error
ON: Error (latch)
OFF: No error
ON: Error
OFF: 16 bit operation mode
ON: 8 bit operation mode
BIN→BCD conversion will not be performed, if a SMOV instruction
is executed after turning on SM8168.
Pulse catch ON when X0 is OFF→ON
Pulse catch ON when X1 is OFF→ON
Pulse catch ON when X2 is OFF→ON
Pulse catch ON when X3 is OFF→ON
Pulse catch ON when X4 is OFF→ON
Pulse catch ON when X5 is OFF→ON.
Pulse catch ON when X6 is OFF→ON.
Pulse catch ON when X7 is OFF→ON.
OFF: No error
ON: Error
OFF: No error
ON: Error
OFF: No error
ON: Error
OFF: No error
ON: Error
OFF: No error
ON: Error
OFF: No error
ON: Error
OFF: No error
ON: Error
OFF: No error
ON: Error
OFF: Data communication in execution
ON: Data communication in nonexecution
OFF: Down count operation
ON: Up count operation
R/W
R/W
R
R
R
R
R
R/W
R
R
R
R
R
R
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
R
R
R
R
R

Advertisement

Table of Contents
loading

Table of Contents

Save PDF