hit counter script

Mitsubishi Electric FX5 User Manual page 370

Melsec iq-f series
Hide thumbs Also See for FX5:
Table of Contents

Advertisement

No.
Name
SD5152
Pulse width measurement cycle maximum value [Low-
order] (CH7)
SD5153
Pulse width measurement cycle maximum value [High-
order] (CH7)
SD5154
Pulse width measurement cycle minimum value [Low-
order] (CH7)
SD5155
Pulse width measurement cycle minimum value [High-
order] (CH7)
SD5160
Pulse width measurement rising ring counter value [Low-
order] (CH8)
SD5161
Pulse width measurement rising ring counter value [High-
order] (CH8)
SD5162
Pulse width measurement falling ring counter value [Low-
order] (CH8)
SD5163
Pulse width measurement falling ring counter value [High-
order] (CH8)
SD5164
Pulse width measurement latest value [Low-order] (CH8)
SD5165
Pulse width measurement latest value [High-order] (CH8)
SD5166
Pulse width measurement maximum value [Low-order]
(CH8)
SD5167
Pulse width measurement maximum value [High-order]
(CH8)
SD5168
Pulse width measurement minimum value [Low-order]
(CH8)
SD5169
Pulse width measurement minimum value [High-order]
(CH8)
SD5170
Pulse width measurement cycle latest value [Low-order]
(CH8)
SD5171
Pulse width measurement cycle latest value [High-order]
(CH8)
SD5172
Pulse width measurement cycle maximum value [Low-
order] (CH8)
SD5173
Pulse width measurement cycle maximum value [High-
order] (CH8)
SD5174
Pulse width measurement cycle minimum value [Low-
order] (CH8)
SD5175
Pulse width measurement cycle minimum value [High-
order] (CH8)
SD5180
Pulse width measurement rising ring counter value [Low-
order] (CH9)
SD5181
Pulse width measurement rising ring counter value [High-
order] (CH9)
SD5182
Pulse width measurement falling ring counter value [Low-
order] (CH9)
SD5183
Pulse width measurement falling ring counter value [High-
order] (CH9)
SD5184
Pulse width measurement latest value [Low-order] (CH9)
SD5185
Pulse width measurement latest value [High-order] (CH9)
SD5186
Pulse width measurement maximum value [Low-order]
(CH9)
SD5187
Pulse width measurement maximum value [High-order]
(CH9)
SD5188
Pulse width measurement minimum value [Low-order]
(CH9)
SD5189
Pulse width measurement minimum value [High-order]
(CH9)
SD5190
Pulse width measurement cycle latest value [Low-order]
(CH9)
SD5191
Pulse width measurement cycle latest value [High-order]
(CH9)
APPX
368
Appendix 2 Special Register List
Description
This register stores the pulse width measurement cycle maximum
value (CH7).
This register stores the pulse width measurement cycle minimum
value (CH7).
This register stores the pulse width measurement rising ring
counter value (CH8).
This register stores the pulse width measurement falling ring
counter value (CH8).
This register stores the pulse width measurement latest value
(CH8).
This register stores the pulse width measurement maximum
value (CH8).
This register stores the pulse width measurement minimum value
(CH8).
This register stores the pulse width measurement cycle latest
value (CH8).
This register stores the pulse width measurement cycle maximum
value (CH8).
This register stores the pulse width measurement cycle minimum
value (CH8).
This register stores the pulse width measurement rising ring
counter value (CH9).
This register stores the pulse width measurement falling ring
counter value (CH9).
This register stores the pulse width measurement latest value
(CH9).
This register stores the pulse width measurement maximum
value (CH9).
This register stores the pulse width measurement minimum value
(CH9).
This register stores the pulse width measurement cycle latest
value (CH9).
R/W
R/W
R/W
R
R
R
R/W
R/W
R
R/W
R/W
R
R
R
R/W
R/W
R

Advertisement

Table of Contents
loading

Table of Contents

Save PDF