Mitsubishi Electric FX5 User Manual page 388

Melsec iq-f series
Hide thumbs Also See for FX5:
Table of Contents

Advertisement

No.
Name
SD9082
Refresh range setting
SD9083
Retry count setting
SD9084
Communication time-out setting
SD9090
Master station/slave station setting
SD9091
Link mode setting
SD9092
Error determination time setting
*1 Varies according to the host station number SD latch setting state.
Latch disabled: R, Latch enabled: R/W
Data logging function
The special registers for data logging function are shown below.
R: Read only, R/W: Read/Write
No.
Name
SD9300
Data logging setting No.1 Data logging register/clear error
code
SD9301
Data logging setting No.2 Data logging register/clear error
code
SD9302
Data logging setting No.3 Data logging register/clear error
code
SD9303
Data logging setting No.4 Data logging register/clear error
code
Latch area
The special registers for latch area are shown below.
R: Read only, R/W: Read/Write
No.
Name
SD9350
Operation mode setting
SD9351
CPU module auto exchange function restoration target
data setting
SD9352
CPU module auto exchange function setting
APPX
386
Appendix 2 Special Register List
Description
This register stores the refresh range setting.
This register stores the retry count setting.
This register stores the communication time-out setting.
The master station/slave station settings are stored.
The link mode settings are stored.
The error determination time setting is stored.
Description
The cause of the error that occurred when SM9300 (Data
logging register/clear flag) is ON (register)/OFF (clear) is
stored.
0: No error
Other than 0: Error codes
The cause of the error that occurred when SM9301 (Data
logging register/clear flag) is ON (register)/OFF (clear) is
stored.
0: No error
Other than 0: Error codes
The cause of the error that occurred when SM9302 (Data
logging register/clear flag) is ON (register)/OFF (clear) is
stored.
0: No error
Other than 0: Error codes
The cause of the error that occurred when SM9303 (Data
logging register/clear flag) is ON (register)/OFF (clear) is
stored.
0: No error
Other than 0: Error codes
Description
Set the operation mode of backup.
0: Normal Mode
1: CPU module auto exchange function (Deleting existing data)
2: CPU module auto exchange function (Holding existing data)
Set the target data restored with the CPU module auto exchange
function.
0: Only device/label data
1: All target data
2: All target data excluding device/label data
Set the target data restored with the CPU module auto exchange
function.
b15
b14
0
b1: Initialize during CPU module auto exchange function
b14: Restoration for the special relay and special register (CPU
module auto exchange function)
b15: Setting of operation after CPU module auto exchange
function
R/W
R
R
R
R
R
R
R/W
R
R
R
R
R/W
R/W
R/W
R/W
b1
0

Advertisement

Table of Contents
loading

Table of Contents