24 | Service menu
8.4
Info menu
Heating system settings and measurements are displayed in
this menu. No changes can be made.
Menu item
Possible values
Outdoor Temp.
– 40...122 °F
(
)
( – 40...50 °C)
Appl. oper.
ON
OFF
Appl.set sply
68...194 °F (20...90 °C)
Appl.act.sply
68...194 °F (20...90 °C)
Appl.max.sply
95...194 °F (35...90 °C)
LLH Temp.
68...194 °F (20...90 °C)
HC Operation
OFF
Heating
Setback
Summer
Manual
HC set.sply
68...194 °F (20...90 °C)
HC act. sply.
68...194 °F (20...90 °C)
Set Room Temp
OFF
41...86 °F (5.0...30.0 °C) Desired room temperature
Room Temp.
41...86 °F (5.0...30.0 °C) Measured room temperature
DHW Operation
ON
OFF
Set DHW Temp
59...176 °F (15...80 °C)
DHW Temp.
59...176 °F (15...80 °C)
Table 10 Info menu
6 720 821 651 (2017/05)
Description
The currently measured outdoor temperature is available only if an outdoor
temperature sensor is installed.
Burner operating
Burner not operating
Supply temperature required at the heat source (set temperature)
Supply temperature measured at the heat source (actual temperature)
Maximum supply temperature set at the heat source
Current hot water temperature in the low-loss header
Current operating mode of assigned heating zone, User interface operating
instructions
Required supply temperature in assigned heating zone
Measured supply temperature in heating system
Heating switched off, e. g. in the summer
Water heating active
Water heating not active
Desired hot water temperature
Measured hot water temperature
CRC200