2.4
Technical Data
Fig. 4
Dimensions
Dimensions (W × H × D)
Rated voltage
Nominal current
BUS interface
Control range
Permissible ambient
temperature
Protection class
Protection
Table 2
Technical Data
2.5
Accessories
Function modules of the EMS control system:
•
CZM100: Zone module for up to three heating zones
•
Outdoor temperature sensor for outdoor reset control
types or WWSD (Warm Weather Shut Down) and frost
protection.
Only compatible with the following products:
•
CRC100 and CZM100
Applicability of these instructions to EMS-capable modules
These instructions also apply to the user interface when used in
conjunction with CZM100 (accessory).
CRC200
3 3/4"
95 mm
3 3/4" × 3 3/4" × 1 5/16"
(95 × 95 × 33 mm)
( Fig. 4)
8 ... 16 V DC
6 mA
EMS (2-wire BUS)
41 ... 86 °F (5 ... 30 °C)
32 ... 122 °F (0 ... 50 °C)
III
IP20
63/64"
25 mm
2.6
Applicability of the technical documentation
All information related to BUS systems and heating controllers
contained in the technical documentation of e.g. heat sources
applies also to the present user interface.
3
Installation
The detailed system schematics for mounting the hydraulic
assemblies and the associated control devices can be found in
the installation manual of CZM100.
DANGER: Risk of electric shock!
▶ Before installing this product:
Disconnect the heat source and all other
BUS users from the line voltage across all
poles.
3.1
Installation location
This user interface is intended only for wall-
mounted installation. Do not install in the heat
source.
The room in your home where the controller is installed is the
reference room. If room temperature-dependent control is
active, the room temperature in this room serves as the
reference variable for the entire system. If the outdoor reset
control is enabled to factor in the room temperature, the room
temperature functions as an additional reference variable.
The control quality depends on the installation location.
Installation | 7
1 5/16"
33 mm
6 720 811 153-08.1O