hit counter script

Environmental Specifications; Power Requirements - Cisco WS-C2960L-24TS-LL Installation Manual

Catalyst 2960-l series 24-port and 48-port switch
Table of Contents

Advertisement

Environmental Specifications

Environmental Specifications
Environmental Ranges
Operating temperature
3
Storage temperature
Operating relative humidity
Storage relative humidity
Storage altitude
3 Minimum ambient temperature for cold start is 32°F (0°C)
• When using these switches with GLC-T SFP module, the thermal limitations are as follows:

Power Requirements

Power Requirements
AC input voltage
Power rating
Cisco Catalyst 2960-L Series 24-Port and 48-Port Switch Hardware Installation Guide
42
◦ Up to 5000 feet, the operating temperature should not exceed 40°C.
◦ Up to 10000 feet, the operating temperature should not exceed 35°C.
110 to 220 VAC (autoranging)
• 0.27 to 0.41 A, 50 to 60 Hz (Cisco Catalyst 2960L-24TS-LL)
• 1.14 to 2.25 A, 50 to 60 Hz (Cisco Catalyst 2960L-24PS-LL)
• 0.42 to 0.68 A, 50 to 60 Hz (Cisco Catalyst 2960L-48TS-LL)
• 2.17 to 3.83 A, 50 to 60 Hz (Cisco Catalyst 2960L-48PS-LL)
• 0.06 KVA (Cisco Catalyst 2960L-24TS-LL)
• 0.24 KVA (Cisco Catalyst 2960L-24PS-LL)
• 0.09 KVA (Cisco Catalyst 2960L-48TS-LL)
• 0.48 KVA (Cisco Catalyst 2960L-48PS-LL)
23 to 113°F (–5 to 45°C) up to 5,000 ft (1500 m)
23 to 104°F (–5 to 40°C) up to 10,000 ft (3000 m)
-13º to 158ºF (-25º to 70ºC) up to 15,000 ft (4500 m)
5% to 90% (noncondensing)
5% to 95% (noncondensing)
Up to 15,000 ft (4500 m)
Technical Specifications

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws-c2960l-24ps-llWs-c2960l-48ts-llWs-c2960l-48ps-ll

Table of Contents