hit counter script

Specifications; Unit Specifications; Specifications 2-1. Unit Specifications - Sanyo SAP–K91A Technical & Service Manual

Multi-split system air conditioner
Table of Contents

Advertisement

2. SPECIFICATIONS

2-1. Unit Specifications

Indoor Unit
SAP – K91A
Outdoor Unit
SAP – CM1821A
No. of indoor units.
Power Source
Capacity
Air circulation (High)
Moisture removal (High)
Voltage rating
Available voltage range
Running amperes
Power input
Power factor
C.O.P.
Compressor locked rotor amperes
Controls / Temperature control
Control unit
Timer
Fan speeds
Airflow direction (Indoor)
Air filter
Compressor
Refrigerant / Amount charged at shipment
Refrigerant control
Operation sound
Refrigerant tubing connections
Max. allowable tubing length at shipment
Refrigerant tube
diameter
Refrigerant tube kit / Accessories
Unit dimensions
Package dimensions
Weight
Shipping volume
Remarks: Rating conditions are:
Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
BTU/h
m 3 /h
Liters/h
W/W
Indoor / Outdoor
Horizontal
Vertical
Indoor – Hi / Me / Lo
dB-A
Outdoor – Hi
dB-A
Narrow tube
mm (in.)
Wide tube
mm (in.)
Height
Width
Depth
Height
Width
Depth
Net
Shipping
1-unit
240V Single phase 50 Hz
kW
2.50
8,500
430
0.85
V
V
A
5.0
W
1,110
%
93
2.30
A
24
Microprocessor / I.C. thermostat
Wireless remote control unit
1-hour OFF / 12-hour ON or OFF
g
m
Optional / Hanging wall bracket
Indoor Unit
mm
250
mm
790
mm
174
mm
242
mm
850
mm
312
kg
7.0
kg
10.0
m 3
0.06
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2
2-units
Cooling
17,100
430 2
0.85 2
240
216 to 264
2,120
3 and Auto / 1 (Hi)
Manual
Auto
Washable, Anti – Mold
Rotary (Hermetic)
R22 / 1,260 (630 2)
Capillary tube
39 / 37 / 33
53
Flare type
7.5
6.35 (1/4)
9.52 (3/8)
Outdoor Unit
5.00
9.3
95
2.41
48
630
810
275
704
953
369
48.0
52.5
0.25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sap–cm1821aSap–k91a-sSap–cm1821a-s

Table of Contents