No.
Name
SB005F
Completion status of
remote device station
initialization procedure
SB0060
Mode of own station
SB0061
Type of own station
SB0065
Input data status of
own data link faulty
station
SB0066
Number of own station
occupied stations
SB0067
SB006D
Parameter setting
status
SB006E
Operation status of
own station
SB006F
Setting status of block
guarantee of cyclic
data per station
SB0073
Data link setting at
CPU failure
SB0074
Reserved station
specification status
SB0075
Error invalid station
specification status
SB0076
Temporary error invalid
station setting
information
APPX
146
Appendix 5 List of Link Special Relay (SB) Areas
Description
Stores whether the initialization procedure has been completed.
Off: Not completed
On: Completed
Stores the mode setting status of the own station.
Off: Online
On: Mode other than online
Stores the station type of the own station.
Off: Master station (station number: 0)
On: Intelligent device stations (station No.1 to 64)
Stores the setting status of "Input Data from Data Link Faulty Station"
under "Supplementary Cyclic Settings" in "Application Settings" of the own
station.
Off: Clear
On: Hold
Stores the number of occupied stations of the own station.
■1 Stations occupied
• SB0066: Off
• SB0067: Off
■2 Stations occupied
• SB0066: Off
• SB0067: On
■3 Stations occupied
• SB0066: On
• SB0067: On
■4 Stations occupied
• SB0066: On
• SB0067: Off
Stores whether the parameters have been correctly set.
Off: Normal
On: Setting incorrect (An error code is stored in SW0068.)
Stores whether data link with other stations is being performed.
Off: In process
On: Not performed
Stores whether the block guarantee of cyclic data per station has been set
to the own station.
Off: Not set
On: Set
Indicates the data link status specified by the parameter when CPU is
down.
Off: Data link stopped
On: Data link continued
Stores whether a reserved station has been specified by the parameter.
Off: Not specified
On: Specified (The set station number is stored in SW0074 and SW0075)
Depending on the link refresh timing, SB0074 may be updated with the
time difference of one sequence scan from the update of 'Reserved station
specification status' (SW0074, SW0075).
Stores whether an error invalid station has been specified using the
parameter.
Off: Not specified
On: Specified (The set station number is stored in SW0078 and SW0079)
Depending on the link refresh timing, SB0075 may be updated with the
time difference of one sequence scan from the update of 'Error invalid
station specification status' (SW0078, SW0079).
Stores whether a temporary error invalid station has been set.
Off: Not set
On: Set (The set station number is stored in SW007C and SW007D)
Depending on the link refresh timing, SB0076 may be updated with the
time difference of one sequence scan from the update of 'Temporary error
invalid status' (SW007C, SW007D).
Availability
(: Available, : Not available)
Online
Offline
Master
Intelligent
Station
device
station
*1