Chapter 1
Overview
Table 1-4
DC PEM Wiring Definitions
Connector
Input 1
Input 1
Input 2
Input 2
GND
OL-16264-04
Wiring Point
–
48V
RTN
–
48V
RTN
GND
Description
•
Negative DC input from external
battery source
•
Input Voltage Range: – 48VDC to
–
60VDC (nominal), – 40VDC to
–
60VDC (full range)
•
Wiring: #2 Gauge, #4 Gauge
•
Must use Right Angle Power LUG
•
Battery Return for DC input 1
•
Input Voltage Range: – 48VDC to
–
60VDC (nominal), – 40VDC to
–
60VDC (full range)
•
Wiring #2 Gauge, #4 Gauge
•
Must Use Right Angle Power LUG
•
Negative DC input from external
battery source
•
Input Voltage Range: – 48VDC to
–
60VDC (nominal), – 40VDC to
–
60VDC (full range)
•
Wiring: #2 Gauge, #4 Gauge
•
Must use Right Angle Power LUG
•
Battery Return for DC input 1
Input Voltage Range: – 48VDC to
•
–
60VDC (nominal), – 40VDC to
–
60VDC (full range)
•
Wiring #2 Gauge, #4 Gauge
•
Must Use Right Angle Power LUG
•
Earth Ground Connection for PEM
and Chassis
•
Wiring: #2 Gauge, #4 Gauge
•
Must use Right Angle Power LUG
Cisco RF Gateway 10 Hardware Installation Guide
Cisco RFGW-10 Components
1-13