Configuring Online Diagnostics
Command
Step 4
diagnostic monitor threshold switch
number test {name | test-id |
test-id-range | all} failure count count
Step 5
diagnostic monitor switch number test
{name | test-id | test-id-range | all}
Step 6
end
Step 7
show diagnostic {content | post | result
| schedule | status | switch}
Step 8
show running-config
Step 9
copy running-config startup-config
To disable diagnostic testing and return to the default settings, use these commands:
The switch number option is supported only on stacking-capable switches.
Note
•
•
Cisco Catalyst Blade Switch 3130 and 3032 for Dell Software Configuration Guide
48-4
Purpose
(Optional) Set the failure threshold for the health-monitoring tests.
The switch number keyword is supported only on stacking-capable
switches. The range is from 1 to 9.
When specifying the tests, use one of these parameters:
The range for the failure threshold count is 0 to 99.
Enable the specified health-monitoring tests.
The switch number keyword is supported only on stacking-capable
switches. The range is from 1 to 9.
When specifying the tests, use one of these parameters:
Return to privileged EXEC mode.
Display the online diagnostic test results and the supported test suites. See
the
page 48-6
Verify your entries.
(Optional) Save your entries in the configuration file.
To disable online diagnostic testing, use the no diagnostic monitor switch number test {name |
test-id | test-id-range | all} global configuration command.
To return to the default health-monitoring interval, use the no diagnostic monitor interval switch
number test {name | test-id | test-id-range | all} global configuration command.
•
name—Name of the test that appears in the show diagnostic content
command output.
•
test-id—ID number of the test that appears in the show diagnostic
content command output.
•
test-id-range—ID numbers of the tests that appear in the show
diagnostic content command output.
all—All of the diagnostic tests.
•
name—Name of the test that appears in the show diagnostic content
•
command output.
•
test-id—ID number of the test that appears in the show diagnostic
content command output.
•
test-id-range—ID numbers of the tests that appear in the show
diagnostic content command output.
•
all—All of the diagnostic tests.
"Displaying Online Diagnostic Tests and Test Results" section on
for more information.
Chapter 48
Configuring Online Diagnostics
OL-12247-04