6

PROGRAMMING

6
PROGRAMMING
This chapter describes the programs of the Q66DA-G.
When applying any of the program examples introduced in this chapter to the actual sys-
tem, verify the applicability and confirm that no problems will occur in the system control.
6.1

Programming Procedure

Create the program that will execute the digital-analog conversion of the Q66DA-G in the
following procedure.
Start
D/A conversion enable/disable setting
Will scaling function
be performed?
Yes
Scaling enable/disable setting
Scaling upper/lower limit value setting
Will Rate control
be performed?
Yes
Rate control enable/disable setting
Increase/decrease digital limit value setting
Will Warning output
be provided?
Warning output setting
Warning output upper/lower limit value setting
Operating condition setting request (Y9) on
Digital value write
D/A output enable/disable setting
Processing for Warning output
Processing for Error occurrence
End
No
No
Initial setting
No
6.1 Programming Procedure