6
PROGRAMMING
(3) Program conditions
(a) CH1 uses the rate control function (Refer to Section 3.2.4.)
(b) CH2 uses the warning output function (Refer to Section 3.2.3.)
(c) If an error occurs in writing a digital value, an error code is displayed in binary
(4) List of devices
W11
W12
W116
W117
M20,M21
M22,M23
X20
X21
X22
X24
X25
Y30 to Y3B
X120
X127
X129
X12E
X12F
Y121
Y122
Y129
Y12E
Y12F
• CH1 Increase digital limit value: 100
• CH1 Decrease digital limit value: 30
• CH2 Warning output upper limit value: 10000
• CH2 Warning output lower limit value: 3000
If a warning is output, Warning output flag status is read and processing for the
warning output is performed.
coded decimal (BCD) form.
Error code shall be reset after removing of the cause.
Device
*1
CH1 Digital value
*1
CH2 Digital value
*1
Warning output flag
*1
Error code
CH1 Warning output flag
CH2 Warning output flag
Initial setting request signal
Output enable
Digital value write signal
Warning output reset signal
Error code reset signal
Error code display (BCD 3 digits)
Module READY
External power supply READY
Operating condition setting completed flag
Warning output signal
Error flag
CH1 Output enable/disable flag
CH2 Output enable/disable flag
Operating condition setting request
Warning output clear request
Error clear request
*1 Devices used for the automatic refresh function of GX Configurator-DA.
*2 Although channel 1 does not use warning output, these devices are assigned to read out data of
Warning output flag of both channel 1 and 2 at a time.
*3 When the initial setting is made by GX Configurator-DA, X20 is not used.
For details on the MELSECNET/H remote I/O network, refer to the Q Correspond-
ing MELSECNET/H Network System Reference Manual (Remote I/O Network).
Function
*2
*3
6.3 For Use on Remote I/O Network
1
2
3
4
5
QX10 (X20 to X2F)
QY10 (Y30 to Y3F)
6
Q66DA-G
(X/Y120 to X/Y12F)
7
8
6