7 MEMORY CONFIGURATION AND DATA PROCESS
From peripheral device
Set the data following the
peripheral device menu
Write the data set with the peripheral
device into the OS memory
[Transmission process (10)]
Block
5100
Target axis (1: axis 1, 2: axis 2)
transmission
5101
Head positioning data No. (1 to 600)
memory
5102
No. of read/write data (1 to 100)
Read/write request
5103
Read/write block
5110
(Positioning data storage area)
to
6109
* The default value is "0".
(B) Setting positioning data No. 101 to 600 data
The positioning data is set with the following procedures.
No.1 to 100
Write positioning data into buffer
memory
* The details written with the RIWT command (transient transmission) are shown
below.
0: Read/write complete (set by OS)
1: Read request
2: Write request
Using sequence program (brock transmission)
Positioning data
Turn OFF the remote station READY signal
[RX(n
[Transmission process (3)]
Write required positioning data into buffer memory's block
transmission area [5110 to 6109]
Write following items into buffer memory's block
transmission area [5100 to 5103] using TO command:
* Axis that sets positioning data
* Head No. of positioning data to be set
* Size of positioning data to be set
(Up to 100 items can be set at once)
* Setting of write/read
The positioning data set in the block transmission
area [5110 to 6109] is written into the OS memory.
Complete
Which axis
From nth positioning data in OS memory
How many data
Whether to read or write
When reading, the data is read from the OS
memory into here, and when writing, the data set
and stored here is written into the OS memory.
7 - 15
No.101 to 600
+
7)B].(Refer to section 3.4)
[Transmission process (6)]
[Transmission process (6)]
101 items or more
Set data size
100 items or less
• • • User work
• • • D75P2 state
MELSEC-A
*