hit counter script

Chapter 23 Setup Relating To Router; Interface And Tally (Router/Tally); Router Interface Settings (Router Menu); Assigning Switcher Inputs And Outputs To S-Bus Space - Sony MVS-8000X User Manual

Systems, with ccp-8000 series center control panel
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

Setup Relating to Router

Interface and Tally (Router/Tally)

Router Interface Settings
(Router Menu)
In this system, the interface with a router (routing
switcher) uses the S-Bus protocol. It is therefore necessary
to assign inputs and outputs of the switcher and so on to an
S-Bus space.
To carry out this assignment, use the Router/Tally >Router
menu. The assignment is common to the parallel and serial
tallies.
To display the Router menu
In the Engineering Setup menu, select VF6 'Router/Tally'
and HF1 'Router.'
The status area shows the device names to be assigned to
the S-Bus space, the matrix size, source address,
destination address, and level.
The following functions are available here.
• Matrix Size: Assign the switcher matrix of each
switcher processor to S-Bus space, and select the matrix
size and positioning level, source address settings, and
so on.
• External Box: To obtain the signal selection status of
external devices with a parallel input, assign a matrix as
an external selector in the S-Bus space. Make the matrix
size, assignment level, source address, and other
settings.
• Alias Name Gp: Set the group number for an S-Bus
description name to be displayed in the source name
displays for a cross-point operation.
Assigning Switcher Inputs and
Outputs to S-Bus Space
1
In the <Device> group of the Router/Tally >Router
menu, select the device to which the settings apply.
SWR1: Settings apply to switcher 1.
SWR2: Settings apply to switcher 2.
Chapter
Notes
When there are two switchers on the same network, the
SWR2 (second switcher) settings are required. If there
is only one switcher, the settings are not required.
2
In the <Matrix Size> group, select the matrix size.
320 × 348 (Standard): Assign to S-Bus space with the
switcher input/output at 320×348 size.
272 × 274: Assign to S-Bus space with the switcher
input/output at 272×274 size.
182 × 256: Assign to S-Bus space with the switcher
input/output at 182×256 size.
136 × 138: Assign to S-Bus space with the switcher
input/output at 136×138 size.
128 × 128: Assign to S-Bus space with the switcher
input/output at 128×128 size.
3
Turn the knobs to set the parameters for the following
items.
Source: Specify the start address of the matrix source.
Destination: Specify the start address of the matrix
destination.
Level: Specify the level in the S-Bus space.
Knob Parameter Adjustment
1
Source
Source start
address
2
Destination Destination start
address
3
Level
Level
a) The maximum setting values for each matrix size:
705 for [320x348 (Standard)], 753 for [272x274], 843 for [182x256],
889 for [136x138], 897 for [128x128]
b) The maximum setting values for each matrix size:
677 for [320x348 (Standard)], 751 for [272x274], 769 for [182x256],
887 for [136x138], 897 for [128x128]

Router Interface Settings (Router Menu)

23
Setting values
1 to maximum
a)
value
1 to maximum
b)
value
1 to 8
247

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mvs-7000x

Table of Contents