No.
Name
SD6033
CH1 Process alarm lower upper limit value
SD6034
CH1 Process alarm lower lower limit value
SD6058
CH1 Latest alarm code
SD6059
CH1 Latest error code
SD6060
Ch2 Digital output value
SD6061
CH2 Digital operation value
SD6062
CH2 Analog input voltage monitor
SD6063
CH2 Averaging process setting
SD6064
CH2 Time Average/Frequency Average/Moving Average
SD6066
CH2 Maximum value
SD6067
CH2 Minimum value
SD6068
CH2 Scaling upper limit value
SD6069
CH2 Scaling lower limit value
SD6070
CH2 Shifting amount to conversion value
SD6071
CH2 Process alarm upper upper limit value
SD6072
CH2 Process alarm upper lower limit value
SD6073
CH2 Process alarm lower upper limit value
SD6074
CH2 Process alarm lower lower limit value
SD6098
CH2 Latest alarm code
SD6099
CH2 Latest error code
SD6180
Digital input value
SD6181
Digital operation value
SD6182
Analog output voltage monitor
SD6183
HOLD/CLEAR setting
SD6184
HOLD setting value
SD6188
Scaling upper limit value
SD6189
Scaling lower limit value
SD6190
Input value shift amount
SD6191
Warning output upper limit value
SD6192
Warning output lower limit value
SD6218
Latest alarm code
SD6219
Latest error code
FX Compatible area
The special registers for FX compatible area are shown below.
R: Read only, R/W: Read/Write
No.
Name
SD8000
Watchdog timer
SD8001
PLC type and system version
SD8005
Battery voltage
SD8006
Low battery voltage
SD8007
Power failure count
SD8008
Power failure detection period
SD8010
Current scan time
SD8011
Minimum scan time
SD8012
Maximum scan time
SD8013
RTC: Seconds
SD8014
RTC: Minute data
SD8015
RTC: Hour data
SD8016
RTC: Day data
APPENDIX
304
Appendix 2 Special Register List
Description
This register stores the process alarm lower upper limit value.
This register stores the process alarm lower lower limit value.
This register stores the latest alarm code.
This register stores the latest error code.
This register stores the digital output value.
This register stores the digital operation value.
This register stores the analog input voltage value.
This register stores the averaging process setting.
This register stores the time average/frequency average/moving
average.
This register stores the maximum value.
This register stores the minimum value.
This register stores the scaling upper limit value.
This register stores the scaling lower limit value.
This register stores the shifting amount of conversion value.
This register stores the process alarm upper upper limit value.
This register stores the process alarm upper lower limit value.
This register stores the process alarm lower upper limit value.
This register stores the process alarm lower lower limit value.
This register stores the latest alarm code.
This register stores the latest error code.
This register stores the digital input value.
This register stores the digital operation value.
This register stores the analog output voltage value.
This register stores the HOLD/CLEAR setting.
This register stores the HOLD setting value.
This register stores the scaling upper limit value.
This register stores the scaling lower limit value.
This register stores the input value shift amount.
This register stores the warning output upper limit value.
This register stores the warning output lower limit value.
This register stores the latest alarm code.
This register stores the latest error code.
Description
This register stores the watchdog timer.
This register stores the PLC type and system version.
This register stores the battery voltage.
This register stores the low battery voltage.(units: 0.1 V)
This register stores the power failure count.
This register stores the power failure detection period.
When the power supply voltage is 200 V AC, the time can be
change to 10 to 100 ms.
This register stores the current scan time.
This register stores the minimum scan time.
This register stores the maximum scan time.
This register stores the seconds data.
This register stores the minute data.
This register stores the hour data.
This register stores the day data.
R/W
R/W
R/W
R
R
R
R
R
R/W
R/W
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R/W
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R/W
R/W
R
R
R/W
R
R/W
R
R
R
R
R
R
R