Error
Error name
code
3581H
Operation error
3582H
Operation error
3600H
Operation error
3611H
CH1 pulse width,
period setting
error
3612H
CH2 pulse width,
period setting
error
3613H
CH3 pulse width,
period setting
error
3614H
CH4 pulse width,
period setting
error
3615H
CH5 pulse width,
period setting
error
3616H
CH6 pulse width,
period setting
error
3617H
CH7 pulse width,
period setting
error
3618H
CH8 pulse width,
period setting
error
3619H
CH9 pulse width,
period setting
error
361AH
CH10 pulse
width, period
setting error
APPENDIX
332
Appendix 3 Error Code
Error details and cause
• Modules subsequent to the bus
conversion module are using an operand
that cannot be used.
• An instruction that cannot be used in an
interrupt routine program is used.
• The channel specified by instructions
using communication functions or built-in
I/O does not have the appropriate
parameter.
• The value of the special register to set
the pulse width and cycle of the PWM/
DPWM instruction is abnormal.
• The value of the special register to set
the pulse width and cycle of the PWM/
DPWM instruction is abnormal.
• The value of the special register to set
the pulse width and cycle of the PWM/
DPWM instruction is abnormal.
• The value of the special register to set
the pulse width and cycle of the PWM/
DPWM instruction is abnormal.
• The value of the special register to set
the pulse width and cycle of the PWM/
DPWM instruction is abnormal.
• The value of the special register to set
the pulse width and cycle of the PWM/
DPWM instruction is abnormal.
• The value of the special register to set
the pulse width and cycle of the PWM/
DPWM instruction is abnormal.
• The value of the special register to set
the pulse width and cycle of the PWM/
DPWM instruction is abnormal.
• The value of the special register to set
the pulse width and cycle of the PWM/
DPWM instruction is abnormal.
• The value of the special register to set
the pulse width and cycle of the PWM/
DPWM instruction is abnormal.
Action
• Modify the program so that no operand
whose use is disabled for modules
subsequent to the bus conversion module is
used.
• Modify the program so that no instruction
whose use is disabled by the interrupt
routine program is used.
• Verify that the parameter setting of the
channel specified by instructions using
communication functions or built-in I/O is
correct.
• Modify the value of the special register and
restart PWM.
• Modify the value of the special register and
restart PWM.
• Modify the value of the special register and
restart PWM.
• Modify the value of the special register and
restart PWM.
• Modify the value of the special register and
restart PWM.
• Modify the value of the special register and
restart PWM.
• Modify the value of the special register and
restart PWM.
• Modify the value of the special register and
restart PWM.
• Modify the value of the special register and
restart PWM.
• Modify the value of the special register and
restart PWM.
Detailed
Diagnostic
information
timing
Error location
At instruction
information
execution
Error location
At instruction
information
execution
Error location
At instruction
information
execution
Error location
At END
information
instruction
and system
execution
configuration
information
Error location
At END
information
instruction
and system
execution
configuration
information
Error location
At END
information
instruction
and system
execution
configuration
information
Error location
At END
information
instruction
and system
execution
configuration
information
Error location
At END
information
instruction
and system
execution
configuration
information
Error location
At END
information
instruction
and system
execution
configuration
information
Error location
At END
information
instruction
and system
execution
configuration
information
Error location
At END
information
instruction
and system
execution
configuration
information
Error location
At END
information
instruction
and system
execution
configuration
information
Error location
At END
information
instruction
and system
execution
configuration
information