hit counter script

GE L90 Instruction Manual page 563

L90 line current differential system ur series
Hide thumbs Also See for L90:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 9 of 57)
ADDR
REGISTER NAME
24C1
Terminal 2 IG Magnitude
24C3
Terminal 2 IG Angle
Phasor Measurement Unit actual values (Read Only) (4 modules)
2540
PMU 1 Phase A Voltage Magnitude
2542
PMU Unit 1 Phase A Voltage Angle
2543
PMU 1 Phase B Voltage Magnitude
2545
PMU 1 Phase B Voltage Angle
2546
PMU 1 Phase C Voltage Magnitude
2548
PMU 1 Phase C Voltage Angle
2549
PMU 1 Auxiliary Voltage Magnitude
254B
PMU 1 Auxiliary Voltage Angle
254C
PMU 1 Positive Sequence Voltage Magnitude
254E
PMU 1 Positive Sequence Voltage Angle
254F
PMU 1 Negative Sequence Voltage Magnitude
2551
PMU 1 Negative Sequence Voltage Angle
2552
PMU 1 Zero Sequence Voltage Magnitude
2554
PMU 1 Zero Sequence Voltage Angle
2555
PMU 1 Phase A Current Magnitude
2557
PMU 1 Phase A Current Angle
2558
PMU 1 Phase B Current Magnitude
255A
PMU 1 Phase B Current Angle
255B
PMU 1 Phase C Current Magnitude
255D
PMU 1 Phase C Current Angle
255E
PMU 1 Ground Current Magnitude
2560
PMU 1 Ground Current Angle
2561
PMU 1 Positive Sequence Current Magnitude
2563
PMU 1 Positive Sequence Current Angle
2564
PMU 1 Negative Sequence Current Magnitude
2566
PMU 1 Negative Sequence Current Angle
2567
PMU 1 Zero Sequence Current Magnitude
2569
PMU 1 Zero Sequence Current Angle
256A
PMU 1 Frequency
256C
PMU 1 df/dt
256D
PMU 1 Configuration Change Counter
256E
Reserved (4 items)
Phasor measurement unit integer values (read only actual value registers)
2608
PMU 1 SOC timestamp
260A
PMU 1 FRAMESEC timestamp
260C
PMU 1 STAT flags
Remote double-point status inputs (read/write setting registers)
2620
Remote double-point status input 1 device
2621
Remote double-point status input 1 item
2622
Remote double-point status input 1 name
2628
Remote double-point status input 1 events
2629
... Repeated for double-point status input 2
2632
... Repeated for double-point status input 3
263B
... Repeated for double-point status input 4
2644
... Repeated for double-point status input 5
IEC 61850 GGIO5 configuration (read/write setting registers)
26B0
IEC 61850 GGIO5 uinteger input 1 operand
26B1
IEC 61850 GGIO5 uinteger input 2 operand
26B2
IEC 61850 GGIO5 uinteger input 3 operand
26B3
IEC 61850 GGIO5 uinteger input 4 operand
26B4
IEC 61850 GGIO5 uinteger input 5 operand
GE Multilin
RANGE
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
2 to 90
-327.67 to 327.67
0 to 655.35
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
1 to 32
0 to 128
1 to 64
0 to 1
---
---
---
---
---
L90 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
A
0.001
F060
degrees
0.1
F002
V
0.001
F060
°
0.1
F002
V
0.001
F060
°
0.1
F002
V
0.001
F060
°
0.1
F002
V
0.001
F060
°
0.1
F002
V
0.001
F060
°
0.1
F002
V
0.001
F060
°
0.1
F002
V
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
Hz
0.001
F003
Hz/s
0.01
F002
0.01
F001
---
1
F001
seconds
1
F003
seconds
1
F003
---
1
F003
---
1
F001
---
1
F156
---
1
F205
---
1
F102
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
DEFAULT
0
0
0
0
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0 (None)
"Rem Ip 1"
0 (Disabled)
0
0
0
0
0
B-17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents