Device
Item
Target station
(S1)+5
number
(S1)+6
Number of
(S1)+7
resends
Arrival monitoring
(S1)+8
time
Request data
(S1)+9
length
Setting data
Specify the target station number.
(1)
Station number specification
Master station: 125 (7D
)
H
Master operating station: 126 (7E
supporting the submaster function (
8))
Local station, intelligent device station, submaster station: 1 to
120
When 125 (7D
) is set, the module always accesses the master
H
station (station number 0). When 126 (7E
submaster function is used, the module accesses the station
operating as a master operating station.
(2)
Group specification (The target station is on a network other
than CC-Link IE Field Network.)
81
to A0
: All stations in Group No.1 to 32
H
H
Group No.1: 81
Group No.2: 82
Group No.32: A0
(3)
All stations specification
FF
: All stations on the target station network No. (excluding
H
own station)
When executing instructions using the group specification or all
stations specification
• Specify "0000
" or "03FF
" for the target station CPU type
H
H
((S1)+3) (
Page 242, Section 10.2.2 (3))
• The group specification cannot be used for CC-Link IE Field
Network stations.
• Remote RUN or STOP of the target station cannot be confirmed.
Check if the target station was properly set to RUN or STOP.
• Remote RUN/STOP cannot be performed for the station with the
station number already in use or the station with no station number
setting. Correct the error then execute the instruction.
Unused
During instruction execution
For the case where the instruction is not completed within the
monitoring time specified by (S1)+8, specify the number of
times the instruction is resent.
When the instruction is completed
The number of resends performed (result) is stored.
Specify the monitoring time until instruction completion.
If the instruction is not completed within the specified time, the
instruction is resent for the number of resends specified by (S1)+7.
0: 10 seconds
1 to 32767: 1 to 32767 seconds
Specify the request data count (word).
(Word count of data to be stored in own station start device (S2)
where request data is stored)
4: Remote RUN
3: Remote STOP
CHAPTER 10 DEDICATED INSTRUCTIONS
) (only for modules
H
Page 546, Appendix
) is set and the
H
H
H
H
Setting range
Set by
125 (7D
)
H
126 (7E
)
H
1 to 120
User
81
to A0
H
H
FF
H
0
User
0 to 15
User
System
0 to 32767
User
3, 4
User
309
10