The GP.CCPASET instruction sets parameters for a master/local module.
GP.CCPASET
Setting
Internal device
*1
(System, user)
data
Bit
Word
(S1)
(S2)
(S3)
(S4)
(D)
*1
Local devices and file registers set for each program cannot be used.
(1) Setting data
Setting data
Un
(S1)
*2
(S2)
*2
(S3)
*2
(S4)
(D)
*2
When data from (S2) to (S4) are not set, specify dummy devices. To validate/invalidate (S2) to (S4) data, use b0 to b2 of
(S1)+1.
364
Start contact
GP.CCPASET Un
Link direct device
File
J\
register
R, ZR
Bit
Word
Description
Start I/O number of the master/local module of the own station
(00 to FE
: Upper two digits of the I/O number expressed in three
H
digits)
Start device of the own station where control data is stored
Start device of the own station where network configuration settings
are stored
Start device of the own station where reserved station specification is
stored
Start device of the own station where temporary error invalid station
setting is stored
The device of the own station that turns on for one scan upon
completion of the instruction.
If the instruction fails, (D)+1 also turns on.
(S1)
(S2)
Available devices
Intelligent function
module device
register
U\G
(S3)
(S4)
(D)
Index
Constant
Zn
K, H
$
Set by
Data type
16-bit binary
User
Device name
System
Bit
Others