(10)Ver.2-compatible remote input (RX) and Ver.2-compatible remote output (RY)
These areas are used when the remote net Ver.2 mode or remote net additional mode is selected.
• In the remote net Ver.2 mode, data are stored in the remote input (RX) and remote output (RY) in all slave
stations (including Ver.1-compatible slave stations). (
• In the remote net additional mode, data are stored in the remote input (RX) and remote output (RY) in the
Ver.2-compatible slave station. (
(a) Storage location for each station
The storage locations change depending on the number of occupied stations and expanded cyclic setting in
slave stations. The storage locations for each station can be checked using Slave station offset, size
information (Un\G992 to Un\G1503). (
Remote I/O station
(Station No.1, the number
of occupied stations: 1,
remote I/O station points
Master station
setting: 16 points)
Address
Remote input (RX)
Station
4000
RX F to RX 0
H
No.1
4001
RX 1F to RX 10
Station
H
No.2
4002
RX 2F to RX 20
H
4003
RX 3F to RX 30
H
4004
RX 4F to RX 40
H
Station
to
to
No.3
400F
RX FF to RX F0
H
4010
RX 10D to RX 100
H
4011
RX 11F to RX 110
H
4012
RX 12F to RX 120
H
Station
to
to
No.7
400D
RX 1DF to RX 1D0
H
400E
RX 1EF to RX 1E0
H
to
to
41FC
RX1FCF to RX1FC0
H
41FD
RX1FDF to RX1FD0
H
41FE
RX1FEF to RX1FE0
H
41FF
RX1FFF to RX1FF0
H
Page 54, Section 3.6.5 (3))
Page 335, Appendix 2 (4))
The last two bits of RX/RY cannot be used for communications between the master station and a local station.
(In the example below, RYEE and RYEF cannot be used.)
Remote I/O station
(Station No.2, the number
of occupied stations: 1,
remote I/O station points
setting: 32 points)
X0F
to
X00
X1F
to
X10
X2F
to
X20
Page 50, Section 3.6.4 (3))
Local station
(Station No.3, the number of
occupied stations: 4,
expanded cyclic setting: double)
Remote output (RY)
Address
Station
4200
RY F to RY 0
H
No.1
4201
RY 1F to RY 10
H
Station
No.2
4202
RY 2F to RY 20
H
4203
RY 3F to RY 30
H
4204
RY 4F to RY 40
H
Station
to
to
No.3
RY FF to RY F0
420F
H
RY 10D to RY 100
4210
H
RY 11F to RY 110
4211
H
4212
RY 12F to RY 120
H
Station
to
to
No.7
RY 1DF to RY 1D0
421D
H
RY 1EF to RY 1E0
421E
H
to
to
RY1FCF to RY1FC0
43FC
H
RY1FDF to RY1FD0
43FD
H
RY1FEF to RY1FE0
43FE
H
RY1FFF to RY1FF0
43FF
H
APPENDICES
Local station
(Station No.7, the number of
occupied stations: 4,
expanded cyclic setting: double)
Remote output (RY)
Address
Station
4200
RY F to RY 0
H
No.1
4201
RY 1F to RY 10
H
Station
No.2
4202
RY 2F to RY 20
H
4203
RY 3F to RY 30
H
4204
RY 4F to RY 40
H
Station
to
to
No.3
RY FF to RY F0
420F
H
RY 10D to RY 100
4210
H
RY 11F to RY 110
4211
H
4212
RY 12F to RY 120
H
Station
to
to
No.7
RY 1DF to RY 1D0
421D
H
RY 1EF to RY 1E0
421E
H
to
to
RY1FCF to RY1FC0
43FC
H
RY1FDF to RY1FD0
43FD
H
RY1FEF to RY1FE0
43FE
H
RY1FFF to RY1FF0
43FF
H