6.2.5

DOOR CLOSE (command given via digital inputs)

Description of function
The DOOR CLOSE command closes the door according to the set driving curve and closing
force as long as the command is present. The door reaches the CLOSED position at cutter
speed. Within the cutter distance,
the door is driven with the set cutter force ("Static cutter force CLOSE" parameter). On
reaching the CLOSED position, the door is pressed into the CLOSED position for 2 s with
the closing press-on torque
("Continuous torque CLOSE" parameter). Then, if the DOOR CLOSE command is present,
the door is held closed at a torque that can be adjusted by the parameter "Continuous torque
CLOSE".
Note
If the commands DOOR CLOSE and DOOR OPEN are present simultaneously, the door
always moves in the OPEN direction.
Connection
The "DOOR CLOSE" function is connected to the "CLOSE" input of terminal X6. See also
Section Digital input signals (Page 62).
Signals
Signal
1 (voltage applied)
0 (voltage not applied)
ATE500E
System Manual, 09/2017, A5E33917696-AD
Description
The DOOR CLOSE command is present
The DOOR CLOSE command is not present
Controller