7.6.4.1
i
7.6.4.2
A50010-Y3-C150-2-7619

Rule Creation

For the hiD 6615 S223/S323, you need to open Admin Access Rule Configuration mode
first. After opening Admin Access Rule Configuration mode, the prompt changes from
SWITCH(config)# to SWITCH(config-admin-rule[NAME])#.
To open Rule Configuration mode, use the following command.
Command
rule NAME create admin
After opening Admin Access Rule Configuration mode, a rule can be configured by user.
The rule priority, packet classification and rule action(s) can be configured for each rule.
1. The rule name must be unique. Its size is limited to 63 significant characters.
2. The order in which the following configuration commands will be entered is arbitrary.
3. The configuration of a rule being configured can be changed as often as wanted
(inclusive rule type) until the command, apply, will be entered.
4. Use the command, show rule-profile, to display the configuration entered up to now.

Rule Priority

If rules that are more than two match the same packet then the rule having a higher prior-
ity will be processed first.
To set a priority for an admin access rule, use the following command.
Command
priority { low | medium | high |
highest }
Mode
Opens Admin Access Rule Configuration mode, enter
Global
rule name.
Mode
Sets a priority for a rule.
Admin-rule
(Defaul: low)
UMN:CLI
Description
Description
151