Prepare for Router Installation
When planning your site layout and equipment locations, refer to the General Site Requirements , section. If
you are currently experiencing shutdowns or an unusually high number of errors with your existing equipment,
these precautions and recommendations may help you isolate the cause of failure and prevent future problems.
• Ensure that the room where your router operates has adequate air circulation. Electrical equipment
• Always follow ESD-prevention procedures described in the Preventing Electrostatic Discharge Damage
• Baffles can help to isolate exhaust air from intake air, which also helps to draw cooling air through the
• When equipment installed in a rack (particularly in an enclosed rack) fails, try operating the equipment
Power Guidelines and Requirements
Check the power at your site to ensure that you are receiving power that is free of spikes and noise. Install a
power conditioner if necessary.
Power Guidelines and Requirements lists power requirements for the Cisco 1100 Series ISRs.
Table 5: Power Requirements for Cisco 1100 Series ISRs
Power Source
66W AC Power Adapter
(PWR-66W-AC-V2)
125W AC Power Adapter
(PWR-125W-AC)
115W AC Power Adapter
(PWR-115W-AC)
30W AC Power Adapter
Network Cabling Specifications
The following sections describe the cables and thee specifications required to install Cisco 1100 Series ISRs:
generates heat. Without adequate air circulation, ambient air temperature may not cool equipment to
acceptable operating temperatures.
to avoid damage to equipment. Damage from static discharge can cause immediate or intermittent
equipment failure.
chassis. The best placement of the baffles depends on the airflow patterns in the rack, which can be found
by experimenting with different configurations.
by itself, if possible. Power off other equipment in the rack (and in adjacent racks) to allow the router
under test a maximum of cooling air and clean power.
Hardware Installation Guide for the Cisco 1000 Series Integrated Services Router
Input Rated
100-240V, 2A
100-240 VAC, 2A, 50-60 Hz
100-240VAC, 2A, 50-60 Hz
-
Power Guidelines and Requirements
Output Rated
12 VDC, 5.5A
12VDC, 3.5A; -53.5Vdc, 1.55A
12V, 4.6A, -53.5V 1.12A
-