hit counter script

Siemens SITRANS LR560 Operating Instructions Manual page 106

Foundation fieldbus radar level transmitter
Hide thumbs Also See for SITRANS LR560:
Table of Contents

Advertisement

2.4.8. TVT (Auto False Echo Suppression) Setup
Notes:
• Default settings in the parameter tables are indicated with an asterisk (*)
unless explicitly stated.
• We recommend using AFES Wizard. See
Suppression) Wizard1.2.
2.4.8.1.
Used together with Auto False Echo Suppression Range (2.4.8.2.) to screen
out false echoes in a vessel with known obstructions. A 'learned TVT' (time
varying threshold) replaces the default TVT over a specified range.
a)
b)
c)
Before Auto False
Echo Suppression
Page 100
SITRANS LR560 (FF) – INSTRUCTION MANUAL
on page 87.
Auto False Echo Suppression
Make sure material level is below all known obstructions when
Auto False Echo Suppression is used to learn the echo profile. (An
empty or almost empty vessel is recommended.)
Determine Auto False Echo Suppression Range. Measure the actual
distance from the sensor reference point to the material surface
using a rope or tape measure.
Subtract 0.5 m (20") from this distance, and enter the resulting value
in Auto False Echo Suppression Range.
TVT Hover
Level
AFES (Auto False Echo
false echo
material
level
default TVT
echo marker
7ML19985LY01

Advertisement

Table of Contents
loading

Table of Contents