hit counter script

Siemens SITRANS LR560 Operating Instructions Manual page 110

Foundation fieldbus radar level transmitter
Hide thumbs Also See for SITRANS LR560:
Table of Contents

Advertisement

2.5.3. Channel
Used to select the Transducer Block output. See the manual, Foundation
Fieldbus for Level instruments (7ML19985MP01) for more detail.
Options
* Level (SV1 - Secondary Value 1)
Distance (SV2 - Secondary Value 2)
2.5.4. Input Scaling
Input scaling should match the XD_scale from the Level Transducer Block. See
the manual
more detail.
2.5.4.1.
Defines the operational lower range value of the input value (Process Value
Scale) in Level Units. Process Value Scale normalizes the input value to a
customer-defined range.
Values
2.5.4.2.
Defines the operational upper range value of the input value (Process
Value Scale) in Level Units. Process Value Scale normalizes the input value
to a customer-defined range.
Values
Page 104
SITRANS LR560 (FF) – INSTRUCTION MANUAL
Distance (SV2)
Level (SV1)
Low Calibration Point
(process empty level)
Foundation Fieldbus for Level instruments (7ML19985MP01)
Lower Value
Upper Value
Output Scale
sensor reference point
High Calibration
Point
(process full level)
Range: -999999 to 999999
Default: 0 %
Range: -999999 to 999999
Default: 100 %
Reference Point
Low Calibration Point
sensor reference point
1)
for
Provides Output values
(Out) to AIFB 1 or AIFB 2
7ML19985LY01

Advertisement

Table of Contents
loading

Table of Contents