Repairs

Warning - Danger of frostbite
During repair work on the ACS 500 refrigerant
in liquid or gaseous form can escape and cause
frostbite to the body.
e
Close valves on refrigerant flask.
e
Wear protective goggles.
e
Wear gloves.
9. 1

Opening and closing the ACS 500

9. 1 . 1

Electronic compartment

1
2
3
Fig. 8:
Electronic compartment
Opening the electronic compartment:
1. Remove four self-tapping screws (1).
2. Replace cover (2) backwards and lift upwards.
Closing the electronic compartment:
1. Replace cover (2) and slide forwards underneath the
control panel (3).
2. Secure cover with four self-tapping screws (1).
Robert Bosch GmbH

9. 1 . Cold chamber

2
1
Fig. 9:
Cold chamber
Opening the cold chamber:
1. Remove hexagon socket screws (2).
2. Slide on front cover (1).
Closing the cold chamber:
1. Slide on front cover (1).
2. Secure front cover with four hexagon socket
screws (2).
1
1 689 975 197 (2006-09-22)
en 15