4 AUXILIARY AND APPLIED FUNCTIONS
(b) Station number
Set the station number of SSCNET /H head module.
The same station number can be used for line 1 and line 2.
Cannot use the same station number as the axis No. of the servo amplifier.
(Example) When using servo amplifier setting "d01", cannot set station
number to "1".
Setting range
1 to 64
(c) Axis No.
Set the axis No. of SSCNET /H head module.
(For Motion SFC programs, this number is used for specifying).
Cannot use the same axis No. for line 1 and line 2.
The same Motion axis No. and axis No. can be used.
Communication is not executed with a station that has axis No. set to "0".
(Use as a reserved axis.)
There can be duplicate axis No. 0.
Setting range
0 to 8
(d) Refresh device setting (CPU side)
Set the device (RX, RWr, RY, RWw) for storage of link data.
Motion CPU device is set using automatic refresh by cyclic transmission of
the SSCNET /H head module.
Link devices (RX, RWr, RY, RWw) of the Motion CPU are automatically
assigned in MT Developer2.
POINT
Link devices (RX, RWr, RY, RWw) of the Motion CPU are used only for internal
processing. These cannot be used in user data such as Motion SFC programs etc.
1) Device name
Set the device name that stores link data.
• Bit device
• Word device : D, W, #, U \G
2) Points
Set the points of the device that stores link data. Set the points of the
device in units of words.
The total points for bits and words must be 64 bytes or less.
Bit device (X, Y, M, B)
Word device (D, W, #, U \G)
(Note-1): Set in units of 16 points (1 word).
: X, Y, M, B
Device
(Note-1)
4 - 106
Setting range
16 to 512
1 to 32