hit counter script
Honeywell themis plus EI3 Operating Instructions Manual

Honeywell themis plus EI3 Operating Instructions Manual

Electronic index

Advertisement

03251009
1000248560-002-05
www.docuthek.com
D
GB
I
Operating instructions for
operators and installers
Electronic index EI
Contents
Contents
Electronic index EI . . . . . . . . . . . . . . . . . . . . . 
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Checking the usage . . . . . . . . . . . . . . . . . . . . . 
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Operating the electronic index . . . . . . . . . . . . 
Navigating within the menu . . . . . . . . . . . . . . 
Setting the index parameters . . . . . . . . . . . . . 8
Changing the SIM card . . . . . . . . . . . . . . . . . . 9
Changing the battery . . . . . . . . . . . . . . . . . . . . 9
Electrical pulse output. . . . . . . . . . . . . . . . . . 0
Check test. . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Technical data . . . . . . . . . . . . . . . . . . . . . . . . 4
Logistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Safety
Safety
Please read and keep in a safe place
Please read through these instructions
carefully before installing or operating. Following the
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned
in accordance with the regulations and standards
in force. These instructions can also be found at
www.docuthek.com.
Explanation of symbols
• ,  ,  ,  ... = Action
= Instruction
Liability
We will not be held liable for damage resulting from
non-observance of the instructions and non-com-
pliant use.
Safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
DANGER
Indicates potentially fatal situations.
WARNING
Indicates possible danger to life and limb.
CAUTION
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.
Changes to edition .
The following chapters have been changed:
- Checking the usage
- Logistics
GB-1

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell themis plus EI3

  • Page 1: Table Of Contents

    03251009 Safety Safety 1000248560-002-05 Please read and keep in a safe place www.docuthek.com Please read through these instructions Operating instructions for carefully before installing or operating. Following the operators and installers installation, pass the instructions on to the opera- Electronic index EI tor.
  • Page 2: Checking The Usage

    ATEX Checking the usage ▷ The electronic index is suitable for use in po- Electronic index EI for diaphragm gas tentially explosive atmospheres. For the exact meters BK-G...B use (zone), see ATEX sticker on the diaphragm The electronic index EI3 indicates the volume at base gas meter or see “Operating instructions for conditions.
  • Page 3: Navigating Within The Menu

    User keys, selection key and symbols Menu overview ▷ You can navigate through the menu using the user keys and the selection key Symbol Meaning Navigate to the left or the right on each level using the user keys. – Briefly pressing the selection key selects Current meter reading General instructions...
  • Page 4 ▷ “hourly summary” example: Consumption results *H: 01-05-13 18:00->19:00 0000000.00->0000004.00m F01: 0.00m 4.00m F02: 0.00m F03: 0.00m Tariff: F02 UES:0x0240000000000000 ▷ In lines F01 to F03, the current absolute gas ▷ The timeframe is displayed with date and time consumption values of the relevant tariff register are displayed.
  • Page 5 ▷ V is the absolute value of the gas meter reading. Service mode menu overview ▷ In lines F01 to F03, the absolute values of the tariff registers are displayed. ▷ In the “UES” (UNI-TS 11291 event status) field, the current diagnostic information is displayed. Test instructions ▷...
  • Page 6 ▷ Check test for temperature measurement, see Date and time ▷ Information on the date and time display. page 10 (Check test). Pressure Date and time ▷ The current pressure data will be displayed. 2011 – – *Pressure 1013.25mbar :electronic :[800.00, 1600.00]mbar :1013.25mbar ▷...
  • Page 7 ▷ In order to end the measurement, briefly press Meter information: the selection key again. Measurement stops – Software version once the full number of measuring unit revolu- – CRC: software checksum tions has been completed. – Software details ▷ Measurement is terminated automatically after –...
  • Page 8: Establishing An Optical Communications Link

    Event: 4 In the case of event , “Firmware upgrade”, the Establishing an optical Time: 12:18:45 meaning of the additional data is as follows: communications link Date: 12.06.2013 ▷ In order to configure the electronic index for the Info: 0xFFFFFFFFFFFF0104 respective application, the optical communica- tions link must be activated.
  • Page 9: Changing The Sim Card

    Replacing the communication module Changing the battery ▷ TORX screw driver size T20 required. WARNING Risk of explosion in explosion-hazard areas! – As a general rule, maintenance and repair work should be avoided in explosive atmospheres. – Check that the electrical system complies with the special electrical explosion protection re- quirements.
  • Page 10: Electrical Pulse Output

    ▷ To conduct the tests, the thermowell and the Electrical pulse output pressure test point (if available) can be used as a reference for the temperature and pressure WARNING measured by the index. Risk of explosion in explosion-hazard areas! Cyclic test –...
  • Page 11 ▷ In the test procedure described below, it is guar- the master meter have already been taken into anteed that the unit under test always performs account here: full measuring unit rotations. = 100% x (((Q ) / (Q act,N )) - 1) Master meter test procedure The following applies:...
  • Page 12 5 Compare the measurement results with the mas- Pulse test at a constant flow rate (optical interface) ter meter and determine the measuring deviation Master meter test procedure on the unit under test: a) taking into account the inherent error of the master meter: = 100% x (((V x (1+F...
  • Page 13  The accuracy is checked by comparing the flow 5 Select an ambient temperature as a reference rates. The pressure and temperature values of value and bring the climatic chamber to this tem- the unit under test corrected with reference to perature.
  • Page 14: Assistance In The Event Of Malfunction

    72910265, “Retrofit kit external antenna EI3 / 5m” Assistance in the event of composed of: malfunction – service cover -cpl. EA EI3 (32320088) ? Fault – PT screw K40x16 (03017232) ! Cause – GSM antenna L=5m (04271002) • Remedy Spare parts Possible faults and suggested solutions Only the following spare parts are approved: ? The...
  • Page 15: Logistics

    Pulse value V for pulse tests via optical inter- The electrical interfaces feature the following face: parameters: Pulse output: Decimal Pulse – = 26.6 V Gas meter place value V – = 250 mA in display in dm – = 414 mW BK-G6 –...
  • Page 16: Contact

    Contact Contact United Kingdom Elster Metering Limited Paton Drive Tollgate Business Park Beaconside Stafford, ST16 3EF Tel. +44 1785 275200 Fax +44 1785 275305 jeavons.info@gb.elster.com www.elstermetering.co.uk Ireland Germany Active Energy Control Ltd. Elster GmbH Unit 4, Clare Marts Strotheweg 1 Quin Road 49504 Lotte Ennis, Co.

Table of Contents