hit counter script

Siemens Sinumerik 840D Series Function Manual page 151

Hla module
Hide thumbs Also See for Sinumerik 840D Series:
Table of Contents

Advertisement

04.00
10.03
Velocity controller
disable
5402
SPEED_CTRL_DISABLE_STOPTIME
Braking time for controller disable
Unit:
Default:
ms
0.0
5404
POWER_DISABLE_DELA Y
Power disable timer
Unit:
Default:
ms
100
Setup mode
Function switch
5012
FUNC_SWITCH
Status word (PLC readable) Drive ready
Bit 2=0: Drive signaled as ready if not drive alarm is pending
Bit 2=1: Drive signaled as ready if not drive alarm is pending
and terminals 63, 64, 48 and 663=1
Bit 4=1: ZK2 parameterization error
Bit 14=1: Valid offset between machine zero and actual value zero
Bit 15=1: Valid offset between piston zero and machine zero
Unit:
Default:
-
4
SIMRDY
 Siemens AG, 2003. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Mode of operation when "Velocity controller enable" bit is set:
S
Valve setpoint is output by the velocity controller
S
I-component is enabled
S
Valve spool monitor is activated
If a velocity controller disable is requested, a zero velocity setpoint is output.
S
The braking time set in MD 5402 acts as a speed setpoint adjustment ramp
(acceleration limitation).
S
The setting in MD 5402 corresponds to the time required by the braking
ramp to decelerate the cylinder from the speed in MD 5401 down to zero.
This ramp is effective only when the velocity controller is disabled since, in
this case, the acceleration limits programmed in the control are ignored.
Otherwise, the control system has the responsibility of limiting acceleration
rates.
S
If velocity controller disable followed by a power disable is requested
(MD 5530 bit 3=0), then the delay set in MD 5404:
POWER_DISABLE_DELAY is left to run down after the velocity controller
disable request until the power disable signal is set. If MD 5530, bit 3=1,
MD 5404 has no meaning (drive continues to operate under closed-loop
control with a zero velocity setpoint following a velocity controller disable
request).
Minimum:
Maximum:
0.0
120000.0
Minimum:
Maximum:
0
100000
If the setup mode terminal (term. 112 on mains supply module) is selected, the
velocity setpoint is limited to the value programmed in MD 5420.
Minimum:
Maximum:
0
65535
Only bits 2 and 4 are relevant for the user.
This LED indicates that the drive unit is ready (SIMODRIVE Ready terminal
72/73 -> device bus; cannot be changed by MD 5012).
4 Firmware Drive Functions
4.12 Terminals
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
FLOAT
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
FLOAT
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
UNS.WORD
Immediately
4-151

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digitalSinumerik 840dieSinumerik 840dSinumerik 840deSinumerik 840di

Table of Contents