10.03
10.03
7.3.2
Connection diagrams
Pin 1
5
2
15
14
9
1
12
11
Housing
HLA module
Item
1
Sub D male connector, 15-pin, with screw lock UNC 4-40
6FC9341-1HC
2
Signal lead 2x(2x0.18) C
6FX2008-1BD71
3
Male connector
S
S
Order No. (MLFB) of signal lead for pressure sensors: 6FX2002-2AD00-1 VVV
Fig. 7-10
Signal lead for pressure sensors (X111/X112)
Siemens AG, 2003. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Note
The following cable data for hydraulic systems is tailored specifically to Bosch
Rexroth products. If hydraulics components supplied by other manufacturers
are used, the pin assignments of the hydraulic-end connections might be
different!
Cable print (order no., length in m, manufacturer,
month/year of manufacture)
Length according to length code
Note: Max. approved system cable length 40 m
2
1
M24EXT
0,18
P24DS
0,18
PIST1AP
0,18
PIST1AN
0,18
Shield
M24EXT
0,18
P24DS
0,18
PIST1BP
0,18
PIST1BN
0,18
Shield
Meaning
4-pin socket included with pressure sensor
Bosch Rexroth order no.: 1 834 484 061 or 1 834 484 063
7-pin socket not included with pressure sensor
Bosch Rexroth order no.: 1 834 484 141
7 Peripherals/Accessories
7.3 Pressure sensor
O
B
3
bk
Uext. 0 V
bn
Uext. 24 V
rd
Actual value, 0...10 V
or
Actual value, ground
bk
Uext. 0 V
bn
Uext. 24 V
rd
Actual value, 0...10 V
or
Actual value, ground
Pressure sensor A or B
1) Shield insulated
3
O
2
1
3
4
1)
3
B
2
1
3
4
1)
7-231