hit counter script

Siemens Sinumerik 840D Series Function Manual page 157

Hla module
Hide thumbs Also See for Sinumerik 840D Series:
Table of Contents

Advertisement

02.99
10.03
5622
PROG_SIGNAL_ADDRESS
Address of variable signaling function
Unit:
Default:
HEX
0
5623
PROG_SIGNAL_THRESHOLD
Threshold of variable signaling function
Unit:
Default:
HEX
0
5624
PROG_SIGNAL_HYSTERESIS
Hysteresis of variable signaling function
Unit:
Default:
HEX
0
 Siemens AG, 2003. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Minimum:
Maximum:
0
FFFFFF
Enter the address of the memory location to be monitored by the variable
signaling function.
Note
This machine data is effective only if the signal number is set to 0 (see MD
5621).
Minimum:
Maximum:
0
FFFFFF
Enter the threshold for the memory location address entered in MD 5622:
PROG_SIGNAL_ADDRESS which is to be monitored by the variable signaling
function. In combination with MD 5624: PROG_SIGNAL_HYSTERESIS, this
defines the actual value to be checked by the monitoring function (see diagram
under MD 5620, Fig. 4-21).
Note
Depending on machine data MD 5620: PROG_SIGNAL_FLAGS, the numerical
value entered in MD 5624 is interpreted as an unsigned value (bit 2 = 0) or a
signed value (bit 2 = 1).
Minimum:
Maximum:
0
FFFFFF
Enter the hysteresis (tolerance band) for the memory location address entered
in MD 5622: PROG_SIGNAL_ADDRESS which is to be monitored by the vari-
able signaling function. In combination with MD 5623:
PROG_SIGNAL_THRESHOLD, this defines the actual value to be checked by
the monitoring function (see diagram under MD 5620, Fig. 4-21).
Note
Depending on MD 5620: PROG_SIGNAL_FLAGS, the numerical value entered
in MD 5624 is interpreted as an unsigned value (bit 2 = 0) or a signed value
(bit 2 = 1).
4 Firmware Drive Functions
4.13 Monitoring functions
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
UNS.DWORD
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
UNS.DWORD
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
UNS.DWORD
Immediately
4-157

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digitalSinumerik 840dieSinumerik 840dSinumerik 840deSinumerik 840di

Table of Contents